Press [X] or [Y] at each point, then enter the measured value using the keypad
View all Konica Minolta bizhub PRO C1060L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
bizhub PRESS C1070/C1070P/C1060 bizhub PRO C1060L 0 Measure a misalignment between the marks of [1] to [4] printed on the [back] side of the output chart and the marks on the [front] side. [1] - In this figure, the black mark indicates the front side and the blue mark indi- cates the back side. - Measure a misalignment between printing positions in the horizontal direction (X axis) and vertical direction (Y axis). - The measurement value can be entered in units of up to 0.1 mm. - For example, as illustrated in this figure, if the mark of [1] printed on the back side is misaligned 0.5 mm rightward and 0.3 mm downward compared with the front side, ad- just 0.5 mm in the X direction and 0.3 mm in the Y direction. - Write down the measured values so that you do not forget them. back x y 1 Press [X] or [Y] at each point, then enter the measured value using the keypad, [,], or [+] on the screen or the Keypad on the control panel. - If the printing position is misaligned leftward or upward, enter the value with a negative sign (-). If the printing position is misaligned rightward or downward, enter the value with a positive sign (+). - To reset a value, press [Clear]. - To switch the positive sign (+) and negative sign (-), press [+/-]. 5 5-7