LG BG-101A Service Manual - Page 19
Procedure C Continued
View all LG BG-101A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
PROCEDURE C CONTINUED 7 To achieve rearward slope for unit draining, remove the backing from the 1113/16" shim strips and attach them as shown below in Fig. 37. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve. 1" high 3/4" High FIG. 36 Shim (2EA) CAUTION • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils. • Make sure air conditioner does not fall during removal. • If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure. 6" 6" 8 Install the new unit into the wall sleeve 9 Assemble trim as described in Step 6, Procedure A. FIG. 37 Parts and Installation -19-