4 COLUMBUS DRYER CYCLE PROCESS Cycle Default Conditions of operation and termination Drying Cooling Wrinkle care Temp- Dry Display erature Level time Electro- Temp- Default Tempsensor Control time Control** Time Heavy Duty High (Normal) 54min Saturation 70±5°C (5min) 47±5°C Cotton/ Towel Medium High (Normal) 55min Saturation 66±5°C (5min) 47±5°C Normal Medium (Normal) 41min Saturation 62±5°C (5min) 47±5°C Sense Dry * Perm. 3Hr Permanent Low (Normal) 36min Saturation 55±5°C (5min) 47±5°C Press Delicate Low (Normal) 32min Saturation 55±5°C (5min) 38±5°C Ultra Delicate Extra low (Normal) 34min Saturation 45±5°C (5min) 38±5°C Speed dry (High) - 25min Saturation (70±5°C) (5min) (47±5°C) Manual Dry ** Freshen Up (Medium High) - 20min Saturation (66±5°C) (5min) (47±5°C) 3Hr Air dry - - 30min Saturation No heater N/A N/A Load Motor Heater Off Time: 6min On Time: 10sec Temperature Control for each cycle * Sense dry : "Dry Level" is set by users. ** Manual dry : "Temperature control" is set by users. Default settings can be adjusted by users. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

9
Time
COLUMBUS DRYER CYCLE PROCESS
4
Cycle
Heavy Duty
3Hr
3Hr
Off Time: 6min
On Time: 10sec
Temperature Control for each cycle
High
Medium
High
Medium
Low
Low
Extra
low
(High)
(Medium
High)
Cotton/
Towel
Normal
Perm.
Permanent
Press
Delicate
Ultra
Delicate
Speed dry
Freshen Up
Air dry
-
(Normal)
(Normal)
(Normal)
(Normal)
(Normal)
(Normal)
-
-
-
54min
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
55min
41min
36min
32min
34min
25min
20
min
30
min
(5min)
(5min)
(5min)
(5min)
(5min)
(5min)
(5min)
(5min)
N/A
70±5°C
66±5°C
62±5°C
55±5°C
55±5°C
45±5°C
(70±5°C)
(66±5°C)
No
heater
47±5°C
47±5°C
47±5°C
47±5°C
38±5°C
38±5°C
(47±5°C)
(47±5°C)
N/A
Saturation
Load
Sense
Dry *
Manual
Dry **
Default
Drying
Electro-
sensor
Temp-
Control
Default
time
Temp-
Control**
Cooling
Wrinkle care
Conditions of operation and termination
Temp-
erature
Dry
Level
Display
time
Motor
Heater
* Sense dry : “Dry Level” is set by users.
** Manual dry : “Temperature control” is set by users.
Default settings can be adjusted by users.