LG DLG5932W Service Manual - Page 23
Test 6 - not heating up
View all LG DLG5932W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Test 6 Heater switch test - Electric Type Caution Before measuring resistance, be sure to turn Power off, and do voltage discharge. (When discharging, contact the metal plug of Power cord with earth line.) Trouble Symptom While operating, Heating will not work. Drying time takes longer. Measurement Condition After turning Power off, measure the resistance. TH3 TH2 1. Is resistance between Heater terminal and below 18 ~ 22Ω? 2. Is resistance between Heater terminal and below 18 ~ 22Ω? 3. Is resistance between Heater terminal and below 9 ~ 11Ω? NO • Replace Heater. YES Check if the value of measured resistance is below 1Ω between terminal TH2 (Safety Thermostat). NO YES • Replace TH2 (Safety Thermostat). Check if the value of measured resistance is below 1Ω between terminal TH3 (HI-Limit Thermostat). NO YES • Replace TH3 (HI-Limit Thermostat). Check Motor. Check if the value of measured resistance is below 1Ω between terminal NO and at RUN condition. • Check Motor and replace it. YES Check Controller. Check Harness-linking Connector. 22