Page 13 highlights
Component 13. Outlet Thermostat (Auto reset) • Check Top Marking : N95 13. Outlet Thermostat (Manual reset) • Check Top Marking : N100 Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞ Continuity < 1Ω Remark • Gas type • Gas funnel Measure resistance of terminal to terminal Open at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 12
12
Component
Test Procedure
Check result
Remark
13. Outlet Thermostat
(Auto reset)
• Check Top Marking
:
N95
Measure resistance of terminal
to terminal
Open at 203 ± 7°F (95 ± 5°C)
Close at 158 ± 9°F (70 ± 5°C)
Resistance value
∞
Continuity < 1Ω
• Gas type
• Gas funnel
13. Outlet Thermostat
(Manual reset)
• Check Top Marking
:
N100
Measure resistance of terminal
to terminal
Open at 212 ± 12°F
(100 ± 7°C)
Manual reset
If thermal fuse is open must
be replaced
Resistance value
∞
Continuity < 1Ω
• Gas type
• Gas funnel