LG LP1010SNR Owner's Manual - Page 20
Care And Clearing - what is p2
UPC - 048231363068
View all LG LP1010SNR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
CARE AND CLEARING WATER DRAINAGE Using the Upper Drain Port ( Dry Mode Only) This product has a self-evaporative system. The condensing water will be recycled to cool the condenser. This can not only improve cooling efficiency, but also save energy for you. · When need dehumidification in high humidity · Under the Cool or Fan mode, there`s no need of water drainage · During dehumidifying mode, remove the drain plug and the exhaust hose from the back of the unit. · ,QVWDOODGUDLQKRVHijPPLQQHUGLPHQVLRQ DQGSODFHWKHRSHQ end of the hose a suitable drain location or outdoors. · If the internal water container is full, the LCD-display will flash "P2" and the unit will stop automatically. Note: If the water full alarm is often on, there may be some malfunction about the unit. Contact the professional service for help. Using the Bottom Drain Port When the internal water collection tank is full, the air conditioner will turn off until the tank is emptied. Unplug the air conditioner, disconnect the exhaust hose from the back, and move the air conditioner to a suitable drain location or outdoors. You may also place a pan under the drain that will hold up to 1 quart of water. Remove the drain cap from the drain outlet. Once the water collection tank is drained,reinstall the drain cap, making sure it is on securely. Place the air conditioner in the desired location, reconnect the exhaust hose, and plug in the air conditioner. NOTICE P2 apperars in the display The water collection tank is full, drain the tank and reset your setting. YW