LG LSC27914SB Owner's Manual - Page 78

Troubleshooting With Error Display

Page 78 highlights

2. Troubleshooting With Error Display 1) Abnormal Freezer Sensor Error NO. CHECKING FLOW Check for a loose connection in CON6 1 RESULT & SERVICE ACTION Result Firmly plugged Loose Service Action Go to Step 2 Unplug connector and check between White to White as is shown in the picture. 2 1) Remove the Cover Sensor. 2) Cut Sensor and check resistance value. 3 Result 0 Ù Short Service Action Go to Step 3 OFF Open Go to Step 4 Other Normal Check the Temperature and Resistance (Temperature Chart #1) Go to Step 6 Temperatures when unit is energized (Refer to Temperature Chart #1) Result 0 Ù Short OFF Open Service Action Replace Product Change the sensor - 77 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

- 77 -
1) Abnormal Freezer Sensor Error
2. Troubleshooting With Error Display
CHECKING FLOW
RESULT & SERVICE ACTION
Check for a loose connection in CON6
Result
Service Action
Firmly plugged
Loose
Go to Step 2
1
Unplug connector and check between
White to White
as is shown in the picture.
2
Result
Service Action
0
Ù
OFF
Go to Step 3
Go to Step 4
Other
Short
Open
Normal
Check the Temperature
and Resistance
(Temperature Chart #1)
Go to Step 6
Temperatures when unit is energized
(Refer to Temperature Chart #1)
NO.
3
1) Remove the Cover Sensor.
2) Cut Sensor and check resistance value.
Result
Service Action
0
Ù
OFF
Change the sensor
Replace Product
Short
Open