LG LSC27914SB Owner's Manual - Page 78
Troubleshooting With Error Display
View all LG LSC27914SB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
2. Troubleshooting With Error Display 1) Abnormal Freezer Sensor Error NO. CHECKING FLOW Check for a loose connection in CON6 1 RESULT & SERVICE ACTION Result Firmly plugged Loose Service Action Go to Step 2 Unplug connector and check between White to White as is shown in the picture. 2 1) Remove the Cover Sensor. 2) Cut Sensor and check resistance value. 3 Result 0 Ù Short Service Action Go to Step 3 OFF Open Go to Step 4 Other Normal Check the Temperature and Resistance (Temperature Chart #1) Go to Step 6 Temperatures when unit is energized (Refer to Temperature Chart #1) Result 0 Ù Short OFF Open Service Action Replace Product Change the sensor - 77 -
- 77 -
1) Abnormal Freezer Sensor Error
2. Troubleshooting With Error Display
CHECKING FLOW
RESULT & SERVICE ACTION
Check for a loose connection in CON6
Result
Service Action
Firmly plugged
Loose
Go to Step 2
1
Unplug connector and check between
White to White
as is shown in the picture.
2
Result
Service Action
0
Ù
OFF
Go to Step 3
Go to Step 4
Other
Short
Open
Normal
Check the Temperature
and Resistance
(Temperature Chart #1)
Go to Step 6
Temperatures when unit is energized
(Refer to Temperature Chart #1)
NO.
3
1) Remove the Cover Sensor.
2) Cut Sensor and check resistance value.
Result
Service Action
0
Ù
OFF
Change the sensor
Replace Product
Short
Open