LG LSC27914SB Owner's Manual - Page 82
Abnormal Refrigerator Sensor Error 2
View all LG LSC27914SB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
3) Abnormal Refrigerator Sensor Error (2) NO. CHECKING FLOW Check for a loose connection. 1 RESULT & SERVICE ACTION Result Firmly plugged Loose Service Action Go to Step 2 Unplug connector in CON 7 and check between Gray to Gray as is shown in the picture. 2 Result 0 Ù Short OFF Open Other Normal Service Action Go to Step 3 Go to Step 4 Check the Temperature and Resistance (Temperature Chart #2) Go to Step 6 1) Remove Cover sensor. 2) Cut sensor and check resistance value. 3 Result 0 Ù Short OFF Open Service Action Replace Product Change Sensor - 81 -
- 81 -
3) Abnormal Refrigerator Sensor Error (2)
CHECKING FLOW
RESULT & SERVICE ACTION
Check for a loose connection.
Result
Service Action
Firmly plugged
Loose
Go to Step 2
Unplug connector in CON
7 and check between
Gray to Gray
as is shown in the picture.
Result
Service Action
0
Ù
OFF
Go to Step 3
Go to Step 4
Other
Short
Open
Normal
Check the Temperature
and Resistance
(Temperature Chart #2)
Go to Step 6
1
2
NO.
1) Remove Cover sensor.
2) Cut sensor and check resistance value.
3
Result
Service Action
0
Ù
OFF
Replace Product
Short
Open
Change Sensor