6
Ventilation
/
Installation
Overview
The
LST-5600A
Integrator
Box
as
well
as
Plasma
monitors
generate
heat
dur-
ing
operation
and
need
to
be
provided
with
adequate
ventilation
to
assure
con-
tinued
reliable
operation.
See
recom-
mendations
below.
Ventilation
Clearance
Proper
clearance
for
air
to
flow
around
the
LST-5600A
Integrator
Box
must
be
provid-
ed.
Monitor
Ventilation
Be
sure
proper
ventilation
is
provided
for
the
monitor,
see
monitor
installation
guide
for
specified
ventilation
require-
ments.
1.
There
are
ventilation
holes
on
three
sides
of
the
the
LST-5600A
box
pro-
vided
for
ventilation
cooling.
a.
If
the
box
is
mounted
vertically,
the
vents
on
the
sides
should
be
located
on
the
top
and
bottom
for
free
vertical
air
movement.
b.
If
the
box
is
mounted
horizontal-
ly,
the
vents
should
be
located
at
the
sides
and
top
of
the
enclo-
sure
(never
mount
the
box
with
vents
facing
down).
2.
The
vent
holes
should
never
be
blocked
or
obstructed
to
airflow
but
have
an
unimpeded
path
through
any
enclosure
back
to
room
temper-
ature
air.
3.
The
unit
and
its
venting,
should
not
be
installed
near
heat
sources
such
as
radiators
or
heating
ducts.
4.
If
the
unit
is
placed
in
an
enclo-
sure,
tests
should
be
run
to
con-
firm
that
the
ambient
temperature
around
the
unit
under
normal
expected
operating
conditions
is
stable
and
does
not
exceed
40
degrees
Celsius
(104F).
This
can
be
determined
by
placing
a
ther-
mometer
near
the
air
intake
vents
in
the
proposed
enclosure
and
measuring
the
temperature
every
hour,
under
normal
operating
con-
ditions,
until
two
successive
read-
ings
repeat.
If
temperature
does
not
stabilize
but
keeps
increasing
above
104F,
ventilation
is
inade-
quate
and
needs
to
be
improved.
5.
Always
provide
adequate
air
space
between
the
ventilation
areas
and
adjacent
structures.
Note
In
addition
to
the
ventilation
require-
ments
shown,
be
sure
to
allow
enough
clearance
(4"
-
5")
for
wiring
clusters
attached
to
the
Integrator
Box.
Vertical
Installation
(Wall
Mount)
Using
Supplied
Angled
L-Brackets
Two
angled
L-brackets
are
provided
so
that
the
Integrator
Box
can
be
mounted
on
a
flat
vertical
sur-
face,
like
a
wall.
Install
the
two
angled
L-brackets
and
the
screws
provided.
Mount
Integrator
Box
on
the
wall
using
four
appropriate
screws.
ote
The
brackets
are
designed
to
be
mounted
to
typical
16"
spaced
wall
studs.
Do
not
mount
the
Integrator
Box
to
a
weak
wall
surface.
If
wall
studs
are
not
available,
use
some
other
appropriate
fastening
system.
Monitor/Integrator
Box
Wall
Mounting
System
The
plasma
monitor
and
Integrator
Box
can
be
mounted
to
a
wall
using
an
optional
Monitor/Integrator
Box
wall
mounting
system.
For
further
information
on
the
mount-
ing
system,
see
your
LG
dealer.
Ventilation
Clearance
Proper
clearance
for
air
to
flow
around
the
LST-5600A
Integrator
Box
must
be
provided,
see
above.
Vent
Holes
Vent
Holes
Vent
Holes
Vent
Holes
Vent
Holes
Vent
Holes