LG M3200C-BA Owner's Manual (English) - Page 45
RS-232C
View all LG M3200C-BA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
RS-232C Controlling the Multiple Product Transmission / Receiving Protocol Transmission [Command1][Command2][ ][Set ID][ ][Data][Cr] * [Command 1]: First command. (j or k) * [Command 2]: Second command. * [Set ID]: You can adjust the set ID to choose desired product ID number in Special menu. Adjustment range is 0 ~ 99. When selecting Set ID '0', every connected TV set is controlled. Set ID is indicated as decimal (0~99) on menu and as Hexa decimal (0x0~0x64) on transmission/receiving protocol. * [DATA]: To transmit command data. Transmit 'FF' data to read status of command. * [Cr]: Carriage Return ASCII code '0x0D' * [ ]: ASCII code Space (0x20)' OK Acknowledgement [Command2][ ][Set ID][ ][OK][Data][x] * The Product transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer. Error Acknowledgement [Command2][ ][Set ID][ ][NG][Data][x] * The Product transmits ACK (acknowledgement) based on this format when receiving abnormal data from non-viable functions or communication errors. Data 1: Illegal Code 2: Not supported function 3: Wait more time A3