LG RCS10MPA Service Manual - Page 26

Component Test Procedure

Page 26 highlights

CCOOMMPPOONNEENNTT TTEESSTT PPRROOCCEEDDUURREE CAUTIONS 1C. ADIUSCTOIONNNSECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE 1. ODUISTCEORNCNAESCET FTRHEOMPOTWHEERUSNUITP.PPLRYOCCOEREDDFWRIOTMH TTHHEE OTEUSTTLEOTNWLYHEANFETVEERRDRISECMHOAVRINGGINTGHETHE HIGH VOOULTTEARGCEACSAEPFARCOITMOTRHAENUDNIRTE. PMROOVCINEGEDTHWEITWH ITRHEELTEEASDTSOFNRLOYMAFTTHEERPDRIISMCAHRAYRGWIINNGDITNHGE OHFIGTHHE HVIOGLHTAVGOELTCAAGPEACTIRTAONRSAFNODRRMEEMRO. (VSINEEG PTHAGE EW2IR-1E) LEADS FROM THE PRIMARY WINDING OF THE 2. AHLIGL HOPVEORLTAATGIOENTARLACNHSEFCOKRSMEWRIT. (HSEMEICPRAOGWEA2V-1E) ENERGY MUST BE DONE WITH A LOAD (1 LITER 2. OAOFLFLWWOAAPTTEEERRRATIINNIOCCNOOANNLTTCAAHIINNEECERRK)S)INIWNTITTHHHEEMOOIVCVERENON.W. AVE ENERGY MUST BE DONE WITH A LOAD (1 LITER COCMOMPOPONENNENTSTS HHIIGGHH VVOOLLTTAAGGEE TTRRAANNSSFFOORRMMEERR ((WWiirree lleeaaddss rreemmoovveedd)) TESTTPERSTOCPREODCUERDEURE RESRUELSTUSLTS SECONDARY TERMINAL FILAMENT WINDING PRIMARY TERMINAL MAGNETRON M(WAiGreNlEeaTdRsOreNmoved) (Wire leads removed) RCS10 Approx.: 0.3~0.5 ohm 1. Meas1u.rMe ethaesureresitshteanrecsei.stance. (Ohm-m(Oethemr s-mcaeltee:rRscxa1lea:nRdxR1xa1n0d0R) x100) Approx.: 100~120 ohm RCS1L0ess than: 1 ohm RFS12 • Primar¥yPwriimndairnygwinding • Secon¥dSaerycownindadrinygwinding Approx.: 0.3~0.5 ohm Approx.: 100~R12F0So1h2m Approx.: 0.1~0.3 ohm Approx.: 70~90 ohm • Filame¥nFtilwamindenintgwinding Less than: 1 oAhpmprox.: 0.1~L0e.3ssothhman: 1 ohm Approx.: 70~90 ohm 2. (••MOPFehiralimams2mu-a.mrerM(¥¥eyOnePFetttwhhieralwimaerimsnmiusn-rdamcerdeirenasynienglittteswghewt:teriaontRiosnnrdgcexdcigrna1seionrgli0.oesug0tu:tnaot0nRodn)dgxcgr1eor0.ou0un0nd)d Less than: 1 ohm Normal: Normal: IInnffiinnNNiittooeerrmmaall:: Infinite Infinite 1. Measure the resistance. 1. Measur(eOthhme -rmeseitsetrasnccael.e: Rx1) (Ohm-m¥eFtielarmsceanltet:eRrmx1in)al • Filament terminal 2. Measure the resistance. 2. Measur(eOthhme -rmeseitsetrasnccael.e: Rx1000) (Ohm-m¥eFtielarmsceanltet:oRcxh1a0s0s0is) • Filament to chassis Normal: Less than 1 ohm Normal: Less than 1 ohm Normal: Infinite Normal: Infinite 5-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
¥ Primary winding
¥ Secondary winding
¥ Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Primary winding to ground
¥ Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
¥ Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Filament to chassis
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
COMPONENT TEST PROCEDURE
Approx.: 0.3~0.5 ohm
RCS10
RFS12
Approx.: 100~120 ohm
Less than: 1 ohm
Approx.: 0.1~0.3 ohm
Approx.: 70~90 ohm