LG RCS10MPA Service Manual - Page 27

Components, Test Procedure, Results

Page 27 highlights

COMPONENTS HIGH VOLTAGE CAPACITOR TEST PROCEDURE Chassis Antenna Antenna GasGkaest ket Chassis RESULTS Filament Filament NOTE: When testing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition. Measure the resistance. (Ohm-meter scale: Rx1000) ¥ Terminal to terminal. Normal: Momentarily indicates several ohms, and then gradually returns to infinite. Measure the resistance. (Ohm-meter scale: Rx1000) ¥ Terminal to case. Normal: Infinite. HIGH VOLTAGE DIODE Measure the continuity (Forward). (Ohm-meter scale: Rx10000) Normal: Continuity. Abnormal: Infinite. NOTE : Some inexpensive meters may indicate infinite resistance in both direction. Measure the continuity (Reverse). (Ohm-meter scale: Rx10000) Normal: Infinite. Abnormal: Continuity. 5-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and
then gradually returns
to infinite.
Normal: Infinite.
Normal: Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament