LG REG-123A Service Manual - Page 9
How to InstallModels with Installaion Kit
View all LG REG-123A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Installation How to Install(Models with Installaion Kit) When Using Gasket REG-123A A 1 A 2 2 B H 3 4 DE F RIGHT SIDE B HORIZONTAL LINE I 1. WINDOW (WIDTH-A, HEIGHT-B) 2. GASKET 3. WALL 4. DETAILS 5.1 x 30 ROUND HEAD WOOD SCREWS A B C D E F H I 625mm (245/8") 392mm (157/16") 280mm (111/32") 30mm (11/16") 0~25mm (0~1") OVER 420mm (OVER 1617/32") 5~10mm -5~5mm (3/16"~3/8") (-3/16"~3/16") When Using Installation Kits 1. Window Requirements This unit is designed for installation in standard double hung windows with actual opening widths from 27" to 39". The top and bottom window sash must open sufficiently to allow a clear vertical opening of 16" from the bottom of the upper sash to the window stool. 27" to 39" 16" min Stool Interior wall Offset 1/2" to 11/4" Sill Exterior 2. Installation Kits Contents 1 2 3 4 5 6 7 8 9 11 13 12 14 235/8" min (Without frame curtain) NO. NAME OF PARTS Q'TY 1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3 BOLT 2 4 NUT 2 5 SCREW(TYPE A) (10mm(2/5")) 16 6 SCREW(TYPE B) D5.1mm(0.2")/16mm(0.63") 3 7 SCREW(TYPE C)D4.1mm(0.17")/16mm(0.63") 5 8 FOAM-STRIP 1 9 FOAM-PE (920mm x 30mm x 2mm) 1 10 UPPER GUIDE 1 11 FOAM-PE (600mm x 25mm x 2mm) 1 12 FRAME GUIDE 2 13 WINDOW LOCKING BRACKET 1 14 DRAIN PIPE 1 s Top retainer bar is in the product package. 10 Service Manual 9