Diagnostic Error Code 001-024-XXX System Addressing test failure 001-025-XXX System Checksum Value error 001-026-XXX System FLASH data error 001-027-XXX System Configuration/Setup error 001-032-XXX System Device Controller failure 001-034-XXX System Device Buffer Allocation failure 001-035-XXX System Device Reset condition detected 001-036-XXX System Register error 001-038-XXX System Extension failure 001-039-XXX System DMI data structure error 001-040-XXX System IRQ failure 001-041-XXX System DMA failure 001-195-XXX System Test aborted by user 001-196-XXX System test halt, error threshold exceeded FRU/Action System board 1. Flash the system. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 2. System board 1. Flash the system. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 2. System board 1. Run Setup 2. Flash the system. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 3. System board System board 1. Reboot the system 2. Flash the system. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 3. Run memory test 4. System board System board System board 1. Adapter card 2. System board 1. Flash the system. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 162 2. System board 1. Power-off/on system and re-test 2. System board 1. Power-off/on system and re-test 2. System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 56 Hardware Maintenance Manual