Keyboard, Printer, ARE THE VOLTAGES CORRECT?
View all Lenovo NetVista A40p manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Keyboard Note: If a mouse or other pointing device is attached, remove it to see if the error symptom goes away. If the symptom goes away, the mouse or pointing device is defective. 001 - Power-off the computer. Disconnect the keyboard cable from the system unit. Power-on the computer and check the keyboard cable connector on the system unit for the voltages shown. All voltages are 5%. Pin Voltage (Vdc) 1 +5.0 2 Reserved 3 Ground 6 5 4 +5.0 4 3 5 +5.0 6 Reserved 2 1 ARE THE VOLTAGES CORRECT? If NO, continue with 002 . If YES, proceed to 003 . 002 Replace the system board. 003 On keyboards with a detachable cable, replace the cable. If the problem remains or if the cable is permanently attached to the keyboard, replace the keyboard. If the problem remains, replace the system board. Printer 1. Make sure the printer is properly connected and powered on. 2. Run the printer self-test. If the printer self-test does not run correctly, the problem is in the printer. Refer to the printer service manual. Chapter 2. Types 6568/6569/6648/6649 29