Lenovo PC 300PL IBM PC 300PL (6565) User Guide (including system setup and opt - Page 25

Specifications: Desktop model

Page 25 highlights

Specifications: Desktop model Dimensions Height: 138 mm (5.43 in.) Width: 400 mm (15.75 in.) Depth: 429 mm (16.9 in.) Weight Minimum configuration as shipped: 9.53 kg (21 lb) Maximum configuration: 10.4 kg (23 lb) Environment Air temperature: - System on: 10° to 35°C (50° to 95°F) - System off: 10° to 43°C (50° to 110°F) Humidity: - System on: 8% to 80% - System off: 8% to 80% Maximum altitude: 2134 m (7000 ft) Electrical input Input voltage: - Low range: - Minimum: 90 V ac - Maximum: 137 V ac - Input frequency range: 57 - 63 Hz - Voltage switch setting: 115 Vac - High range: - Minimum: 180 V ac - Maximum: 265 V ac - Input frequency range: 47 - 53 Hz - Voltage switch setting: 230 Vac - Input kilovolt-amperes (kVA) (approximately): - Minimum configuration as shipped: 0.08 kVA - Maximum configuration: 0.51 kVA Note: Power consumption and heat output vary depending on the number and type of optional features installed and the optional power-management features in use. Heat output Approximate heat output in British thermal units (Btu) per hour: - Minimum configuration: 256 Btu/hr (75 watts) - Maximum configuration: 706 Btu/hr (207 watts) Airflow Approximately 0.5 cubic meters per minute (18 cubic feet per minute) Acoustical noise-emission values Average sound-pressure levels: - At operator position: - Idle: 33 dBA - Operating: 39 dBA - At bystander position-1 meter (3.3 ft): - Idle: 30 dBA - Operating: 34 dBA Declared (upper limit) sound power levels: - Idle: 4.4 bels - Operating: 4.9 bels Note: These levels were measured in controlled acoustical environments according to procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779, and are reported in accordance with ISO 9296. Actual sound-pressure levels in your location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound power levels indicate an upper limit, below which a large number of computers will operate. Chapter 1. IBM PC 300PL and PC 300GL overview 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

Specifications: Desktop model
Dimensions
±
Height:
138 mm (5.43 in.)
±
Width:
400 mm (15.75 in.)
±
Depth:
429 mm (16.9 in.)
Weight
±
Minimum configuration as shipped:
9.53
kg (21 lb)
±
Maximum configuration:
10.4 kg (23 lb)
Environment
±
Air temperature:
System on:
10° to 35°C (50° to 95°F)
System off:
10° to 43°C (50° to 110°F)
±
Humidity:
System on:
8% to 80%
System off:
8% to 80%
±
Maximum altitude:
2134 m (7000 ft)
Electrical input
±
Input voltage:
Low range:
-
Minimum:
90 V ac
-
Maximum:
137 V ac
-
Input frequency range:
57 – 63
Hz
-
Voltage switch setting:
115 Vac
High range:
-
Minimum:
180 V ac
-
Maximum:
265 V ac
-
Input frequency range:
47 – 53
Hz
-
Voltage switch setting:
230 Vac
Input kilovolt-amperes (kVA)
(approximately):
-
Minimum configuration as
shipped: 0.08 kVA
-
Maximum configuration:
0.51
kVA
Note:
Power consumption and heat
output vary depending on the
number and type of optional
features installed and the optional
power-management features in
use.
Heat output
±
Approximate heat output in British
thermal units (Btu) per hour:
Minimum configuration:
256 Btu/hr
(75 watts)
Maximum configuration:
706 Btu/hr
(207 watts)
Airflow
±
Approximately 0.5 cubic meters per
minute (18
cubic feet per minute)
Acoustical noise-emission values
±
Average sound-pressure levels:
At operator position:
-
Idle:
33 dBA
-
Operating:
39 dBA
At bystander position–1 meter (3.3
ft):
-
Idle:
30 dBA
-
Operating:
34 dBA
±
Declared (upper limit) sound power
levels:
Idle:
4.4 bels
Operating:
4.9 bels
Note:
These levels were measured in
controlled acoustical environments
according to procedures specified by the
American National Standards Institute
(ANSI) S12.10 and ISO 7779, and are
reported in accordance with ISO 9296.
Actual sound-pressure levels in your
location might exceed the average values
stated because of room reflections and
other nearby noise sources. The declared
sound power levels indicate an upper
limit, below which a large number of
computers will operate.
Chapter 1.
IBM PC 300PL and PC 300GL overview
7