Timeout/Parity
View all Lenovo ThinkCentre M57 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
Diagnostic Error Code 011-199-XXX Serial port test failed, cause unknown 011-2XX-XXX Serial port signal failure 014-000-XXX Parallel port Interface Test Passed 014-001-XXX Parallel port Presence 014-002-XXX 014-003-XXX Parallel port Timeout/Parity error 014-013-XXX 014-014-XXX Parallel port Control Signal/Loopback test failure 014-015-XXX Parallel port External Loopback failure 014-027-XXX Parallel port Configuration/Setup error 014-03X-XXX 014-04X-XXX Parallel port failure 014-195-XXX Parallel port Test aborted by user 014-196-XXX Parallel port test halt, error threshold exceeded 014-197-XXX Parallel port test warning FRU/Action 1. Go to "Undetermined problems" on page 82 2. Flash the system and re-test. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 442 3. Replace component under function test 1. External serial device 2. System board No action 1. Remove external parallel device, if present 2. Run setup, enable port 3. System board System board System board 1. Wrap plug 2. System board 1. Run Setup, enable port 2. Flash the system. See "Updating (flashing) BIOS from a CD-ROM or diskette" on page 442 3. System board System board Information only Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, "Using the Setup Utility," on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 64 Hardware Maintenance Manual