LiftMaster 98032 LiftMaster Model 98032 Logic Board Instruction Sheet - Englis - Page 3

Warning

Page 3 highlights

ADJUSTMENT TEST THE SAFETY REVERSAL SYSTEM 1. With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2x4 laid flat) on the floor, centered under the garage door. 2. Press the remote control push button to close the door. The door MUST reverse when it makes contact with the board. If the door stops but does not reverse: 1. Repeat Program the Travel (see Adjustment Step 1); 2. Repeat the Safety Reversal test. If the test continues to fail, call a trained door systems technician. TEST THE PROTECTOR SYSTEM® 1. Open the door. Place an obstruction in the path of the door. 2. Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm). The garage door opener will not close from a remote control if the LED in either safety reversing sensor is off (alerting you to the fact that the sensor is misaligned or obstructed). If the garage door opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6 inches [15 cm] above the floor), call for a trained door systems technician. TEST THE POWER DOOR LOCK 1. With the door fully closed, check to ensure that the power lock bolt is visible protruding through the track. 2. Press the button on the remote control to open the garage door. The power door lock should retract before the door begins to move. 3. Press the button on the remote control to close the garage door. When the door reaches the fully closed position, the power door lock should automatically activate to secure the door. NOTE: The power door lock can be manually released by sliding the manual release handle to the open position. However, if the power door lock does not function, contact Chamberlain for a replacement. TEST THE EMERGENCY RELEASE Open the Door Manually: 1. Close the garage door. Slide the manual release handle on power door lock to open before proceeding. 2. Pull down on the emergency release handle until you hear a click. 3. Lift the door manually. Reconnect the Door to the Garage Door Opener: 1. Pull down on the emergency release handle until you hear a click. The door will reconnect on the next UP or DOWN operation. 1. 1. Emergency Release Handle 2. 2. PoPwoerwDeoorr DLoockor Lock MRManeualaenl Rauesaleealse LLoockcBkolBt olt ""LLocokcedk"ed" 3 WARNING Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) high object (or 2x4 laid flat) on the floor. WARNING Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage door ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

3
WARNING
Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
Safety reversal system MUST be tested every month.
After ANY adjustments are made, the safety reversal system
MUST be tested. Door MUST reverse on contact with 1-1/2"
high (3.8 cm) high object (or 2x4 laid flat) on the floor.
WARNING
Without a properly installed safety reversing sensor, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
WARNING
To prevent possible SERIOUS INJURY or DEATH from a falling
garage door:
If possible, use emergency release handle to disengage door
ONLY when garage door is CLOSED. Weak or broken springs
or unbalanced door could result in an open door falling
rapidly and/or unexpectedly.
NEVER use emergency release handle unless garage doorway
is clear of persons and obstructions.
ADJUSTMENT
TEST THE SAFETY REVERSAL SYSTEM
1.
With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a
2x4 laid flat) on the floor, centered under the garage door.
2.
Press the remote control push button to close the door. The door
MUST reverse when it makes contact with the board.
If the door stops but does not reverse:
1.
Repeat Program the Travel (see Adjustment Step 1);
2.
Repeat the Safety Reversal test.
If the test continues to fail, call a trained door systems technician.
TEST THE PROTECTOR SYSTEM®
1.
Open the door. Place an obstruction in the path of the door.
2.
Press the remote control push button to close the door. The door
will not move more than an inch (2.5 cm).
The garage door opener will not close from a remote control if the
LED in either safety reversing sensor is off (alerting you to the fact
that the sensor is misaligned or obstructed).
If the garage door opener closes the door when the safety reversing
sensor is obstructed (and the sensors are no more than 6 inches
[15 cm] above the floor), call for a trained door systems technician.
TEST THE POWER DOOR LOCK
1.
With the door fully closed, check to ensure that the power lock
bolt is visible protruding through the track.
2.
Press the button on the remote control to open the garage door.
The power door lock should retract before the door begins to
move.
3.
Press the button on the remote control to close the garage door.
When the door reaches the fully closed position, the power door
lock should automatically activate to secure the door.
NOTE:
The power door lock can be manually released by sliding
the manual release handle to the open position. However, if the
power door lock does not function, contact Chamberlain for a
replacement.
TEST THE EMERGENCY RELEASE
Open the Door Manually:
1.
Close the garage door. Slide the manual release handle on power
door lock to open before proceeding.
2.
Pull down on the emergency release handle until you hear a click.
3.
Lift the door manually.
Reconnect the Door to the Garage Door Opener:
1.
Pull down on the emergency release handle until you hear a click.
The door will reconnect on the next UP or DOWN operation.
Emergency
Release Handle
Power Door Lock
Manual
Release
Lock Bolt
"Locked"
2.
1.
2.
1.