LiftMaster LA500UL Installation Manual - Page 7
Operator Specifications, External Entrapment Protection Device Inputs non
View all LiftMaster LA500UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
INTRODUCTION Operator Specifications Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight/Length 90 Degree Travel Time* Maximum Travel Range* Maximum Daily Cycle Rate Maximum Duty Cycle Operating Temperature Expansion Board External Entrapment Protection Device Inputs (noncontact and/or contact) Class I, II, III, & IV 120 Vac, 2 Amps (8 Amps including Accessory Outlets) OR 240 Vac, 1 Amp 24 Vdc Transformer Run / Battery Backup 24 Vdc, 500mA max. for ON + SW (switched) 24 Vdc at 60 watts max. 1600 lbs. (725.7kg) / 8 ft (2.4 m) 800 lbs. (362.9 kg) / 16 ft (4.9 m) 600 lbs. (272.2 kg) / 18 ft (5.5 m) 15-18 seconds 115 degrees 300 cycles / day Continuous -40°C to 60°C (-40°F to 140°F) Provided Main board - up to 2 close entrapment protection devices and 1 open entrapment protection device. Expansion board - up to 3 entrapment protection devices configurable to either close or open direction and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU. *Travel time and range are affected by A and B mounting dimensions, see INSTALLATION. 7