LiftMaster SW470 SW490 GL BOARD Manual

LiftMaster SW470 Manual

LiftMaster SW470 manual content summary:

  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 1
    GATE OPERATOR GLCONTROLLER BOARD MODEL SW490 HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial located on electrical box cover) Installation Date INTENDED FOR PROFESSIONAL INSTALLATION ONLY. VISIT WWW.LIFTMASTER.COM TO LOCATE A PROFESSIONAL INSTALLING DEALER IN YOUR AREA. THIS MANUAL
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 2
    Sensor (Hall Effect) Adjustment 19 SAMS (Sequenced Access Management System 20 Accessory Wiring 21-22 Control Board Illustration 23 Controller Programming and Features 24-25 Program Settings 26-27 TROUBLESHOOTING 28-29 MAINTENANCE Operator Maintenance 30 Single Phase Wiring Diagram (SW470
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 3
    OPERATOR DIMENSIONS AND SPECIFICATIONS MODEL SW470 • 1/2 HP Motor Maximum Gate Weight - 500 lbs. (226.8 kg) Maximum Gate Width - 12 ft. (3.7 m) 6.81" (17.3 cm) 24.25" (61.6 cm) 20" (50.8 cm) 10" (25.4 cm) 14.25" (36.2 cm) 13.38" (34 cm) 13.63" (34.6 cm) 13" (33 cm) MODEL SW490 • 1/2 HP Motor
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 4
    UL325 MODEL CLASSIFICATIONS The SW470 and SW490 are intended for use with vehicular swing gates. The opener can be used in Class I, Class II, Class III and Class IV applications. CLASS I - RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one-to
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 5
    * Gate 1 Photo eye for open cycle Photo eye for close cycle Shadow Loop InLteororuppt (Safety) 4' (1.2 m) Typical COMPLEX OR PARKING LOT 1-1/2" (37 mm) Loop Wire* Layer 1/4" (6 mm) or larger depending on loop wire size * REFER TO LOOP MANUFACTURER'S INSTRUCTIONS FOR DETAILED INSTALLATION
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 6
    Exposed Rollers • Vertical Posts • Photoelectric Sensors • Instructional and Precautionary Signage 4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All openings of a horizontal slide gate are guarded or screened from
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 7
    grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade. 1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. 1.6 A gate latch shall not be installed on an automatically operated gate. 1.7 Protrusions shall not
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 8
    protection devices to protect between moving gate and RIGID objects, such as posts. • A swinging gate shall NOT open into public access ways. AVERTISSEMENT WARNING SIGN PALATCTEMEENNT TION WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: CAUTION • Install warning signs on EACH side of
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 9
    INSTALLATION POST MOUNTING (SW470) 1. Locate and anchor two posts made of 3" (7.6 cm) outer diameter heavy walled pipe. Posts should be parallel and square to the gate. IMPORTANT NOTE: The distance between mounting posts and the relative location of the operator to the gate and fence is critical.
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 10
    INSTALLATION PAD MOUNTING (SW470) 1. Layout the concrete pad (Figure 1). IMPORTANT NOTE: The relative location of the operator to the fence and the gate is critical. Be sure that the measurements for operator mounting are taken from the centerline of the fence and of the gate hinge. 2. Locate
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 11
    2 SW490 GATE OPERATOR INSTALLATION TABLE GATE LENGTH (FEET) 8-9 10-11 12-13 14-15 16-17 18-19 20-21 22 P DIMENSION IN INCHES 21.9 25.3 28.8 32.3 35.7 39.2 42.7 46.1 1/2" red head bolts or anchors (4 required) Using suitable hardware secure operator to L-bolts Power and control wiring should
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 12
    Plastic Knob CAUTION If the arm stop is installed incorrectly, the gate will be prevented from opening and damage to the operator may result! Figure 1 Close Stops Left hand Right hand AVERTISSEMENT installation installation SW470 Parallel to Fence ATTCEloseNStopTs ION Arm Channel Housing
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 13
    application. Use any existing hardware necessary to seal the open stop's hole in the operator's cover. 3. Measure the length of the gate panel and select the appropriate extension arm (x) and control arm (Y) dimensions from the gate installation table. 4. Install the control arm hub assembly to the
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 14
    (Inches) Y Dimension (Inches) SW490 Gate Installation Table 8-9 10-11 12-13 14 MANUAL DISCONNECT MODEL SW470 1. Remove the (2) black knobs securing the control arm to the operator (Figure 1). 2. Swing arm assembly off to the side. Gate should swing freely. Figure 1 Arm Channel MODEL SW490
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 15
    power via the operator without consulting the wiring diagram. We recommend that you Install an optional reversing edge BEFORE proceeding with the control station installation. power switch. Upon completion of maintenance the area • ALL power wiring should be on a dedicated circuit and well MUST
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 16
    Cover Wire Nut Connections (See Instructions) Power Wiring Conduit STOP/RESET BUTTON CONTROL WIRING (REQUIRED) 1. This control will function as a Stop/Reset command and is to be wired within line of sight of the gate. The operator will not function unless this circuit is completed. 2. Wire control
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 17
    installing the receiver. To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door: • ALWAYS keep remote controls out of reach of children. NEVER permit children to operate USER SERVICEABLE PARTS. WARNING Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 18
    arm from gate bracket so gate is no longer connected to operator. Push manual release pin(s) OPEN LIMIT SWITCH 8. Turn on power. Press OPEN button (if installed) or connect terminals 5 & 7 on J1 terminal strip. Gate should open. If gate does not open the open limit cam may be already actuating open
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 19
    the sensor board. If a magnet does not clear the board, re-adjust the RPM (hall effect) assembly accordingly. MODEL SW470 Hall Effect Cable Mounting Screw (2) AVERTISSEMENT ATTENTION Hall Effect Bracket Pulley Magnet Pulley MODEL SW490 Mounting Screw (2) Mounting Bracket Hall Effect Cable
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 20
    the many gate operator types and the slide or swing gates allow you to effectively seal off the perimeter of the complex you are planning to secure. NOTE: Connect all entry devices to the slide or swing gate. If using a device, such as a 7-day timer, to latch the slide or swing gate open during high
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 21
    used on swing gate operators. This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. J1 Terminals 6 & 5 - Soft Open These terminals are intended for use as a general open control. Accessories that may be wired to this
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 22
    of site of the gate. This input functions to stop the gate or to reset the gate after an entrapment fault. NOTE: This input uses a normally closed circuit and the operator will not run until a stop control is installed. STOP/RESET BUTTON WIRING R1 R2 R3 R4 3 5 OPEN CLOSE STOP STOP J1 Terminals
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 23
    BOARD ILLUSTRATION Main Terminal Wiring J4 Connector Master/Second Dip Switch #4 Master/Second Potentiometer Timer-to-Close Potentiometer Force Adjustment Dip Switch #2 Dip Switch #1 Diagnostic LED J2 Connector J5 Connector SAMS Relay Drive Troubleshooting LEDs J1 Terminal Troubleshooting
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 24
    different diagnostic codes. LED Code Flashed OFF Diagnostic Meaning Normal operation Cleared By N/A 1 Single entrapment sensed Control Input 2 Double entrapment Hard Input* 3 Failed or no hall effect sensor Removal of problem 4 Exceed maximum motor Hard Input* run time 5 Limit fault
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 25
    is activated On when Alarm Relay is activated TROUBLESHOOTING LEDS There are 9 troubleshooting LEDs. LED D11 D13 D15 D17 (Green) D19 D21 D24 D29 LED NAME Radio Shadow Hard Close Stop Soft Open Hard Open Interrupt (Safety) Loop Obstruction Open D31 Obstruction Close DESCRIPTION On when Radio
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 26
    For all S1, S2 and S4 switch settings to take effect, the Save Mode switch must be set to the off SWING This switch selects slide or swing gate operation, in order to optimize gate behavior for specific application. SL = Slide • SW = Swing RIGHT/LEFT OPERATION This switch selects the gate opening
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 27
    gate configuration accessories may be connected to either the master or second. NOTE: Do not run Master/Second communication wiring in the same conduit as the power and control wiring. The Second unit will require a normally close stop circuit for proper system operation. After Master/Second wiring
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 28
    TROUBLESHOOTING SYMPTOM Operator fails to run. POSSIBLE CAUSES No Stop Control. SOLUTION Check the green LED (D17) on control board. If the green LED is off, check to make sure a stop control has been installed across terminals J1-3 & J1-5 of the control board. Fault in the operator. Check the
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 29
    terminals J1-9 & J1-10 on the control board. Remove the devices and retest. If the operator now runs without fault, check those accessories as well as their wiring. The operator opens immediately upon power up and does not close. The Hall Effect Sensor is not aligned/ adjusted correctly. Check the
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 30
    gate operator SEMENTINJURY or DEATH. properly can increase theArisVk oEf RTI1S0.SSEAMVEETNHTESE INSTRUCTIONS. 5. Use the emergency release only when the gate is not moving. ON AVERTISSEMENT DESCRIPTION TASK CHECK AT LEAST ONCE EVERY 3 MONTHS 6 MONTHS 12 MONTHS RPM Sensor (Hall Effect
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 31
    WIRING DIAGRAM (SW470) 1 PHASE POWER IN SWITCH NOTE 1 MOTOR GROUND GL CONTROL BOARD J2 PLUG 24 Vac - IN 24 Vac - COMMON SOFT OPEN NC "B" LIMIT CONTACTOR B NOTE 1 PRIMARY 24V SEC. SEE NOTE 2 R 2 SEE NOTE 4 ALARM ASSY 76-G0564 "A" LIMIT CONTACTOR A RPM - IN RPM - SUPPLY RPM GND RPM SENSOR
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 32
    SINGLE PHASE WIRING DIAGRAM (SW490) 1 PHASE POWER IN (GN) GROUND (W) (GN) GL CONTROL BOARD 24 Vac - IN 24 Vac -COMMON J2 PLUG (GY) (Y) SOFT OPEN NC "B" LIMIT CONTACTOR B "A" LIMIT CONTACTOR A SEE NOTE 2 230V ONLY SEE NOTE 5 SEE NOTE 1 (W) PRIMARY R1 (BL) 24V Sec. 115 VOLT MOTOR
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 33
    THREE PHASE WIRING DIAGRAM (SW490) SEE NOTE 4 ' ' ' ' 3 PHASE POWER IN ON/OFF SWITCH GL CONTROL BOARD 24 Vac - IN 24 Vac -COMMON J2 PLUG SOFT OPEN NC "B" LIMIT CONTACTOR B SEE NOTE 2 Note 1 24V Sec. ALARM ASSY 76-G0564 B- 460V MOTOR R 2 208/230V MOTOR O/L NOTE 4 575V MOTOR "A"
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 34
    R1 R2 R3 R4 24 Vac NOTE: See wiring diagrams shipped with kit for additional information. See owner's manual for wiring distances and wire gauge information. WARNING: All controls that are to be used to operate the gate system, MUST be installed where the user cannot come into contact with the
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 35
    Cover Sensor Support Bracket On/Off Switch Hall Effect Sensor Assembly Alarm Assembly Side Cover Control Board, GL Transformer, Dual Voltage 24V Limit Switch Capacitor for 115V Capacitor for 230V Mini Contactor 24V ITEM A1 A2 A3 A4 A5 A6 A7 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 SERVICE KITS PART
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 36
    ILLUSTRATED PARTS - SW470 A2 A3 D8 D9 D3 1 A7 A1 A4 A6 A5 9 D1 D12 6 4 D2 D4 D11 10 3 5 7 D10 13 D6 1 8 2 D5 D7 11 14 12 36
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 37
    32-2001 75-G0400 75-G0401 K74-18382 80-1003 31-2712 80-207-19 80-207-23 80-207-25 Gear Reducer Single Swing Collar Double Swing Collar Hall Effect Sensor Assembly Tinnerman Nut Nylon Spacer Key 1/4x1/4x1-1/2" Key 3/16x1-3/8" Key 3/8x3/8x2-1/4" 03-8024-K 21-3260-1 24-115-1 24-230-5 25-2006
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 38
    ILLUSTRATED PARTS - SW490 A5 A1 A4 A3 A5 A2 D10 A7 D11 D5 D21 D20 D1 D12 D18 D12 D17 D4 D3 6 3 D14 D15 D6 D19 D13 8 1 A6 5 2 4 D7 D16 D2 E5 E3 D8 D9 F E1 7 E4 E2 38
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 39
    SW490-33-11 SW490-50-11, SW490-100-21 SW490-75-11 SW490-100-11 SW490-100-53-G, SW490-75-53-G SW490-100-43-G SW490-100-23-G, SW490-100-83-G SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION The following devices are acceptable for Safety Accessories for secondary entrapment protection. MODEL
  • LiftMaster SW470 | SW490 GL BOARD Manual - Page 40
    SPANS AMERICA FOR INSTALLATION AND SERVICE INFORMATION, CALL OUR TOLL FREE NUMBER 1-800-528-2806 www.liftmaster.com WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Technical Support Group 6020
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

CONTROLLER BOARD
GL
MODELS SW470 AND SW490 ARE FOR VEHICULAR PASSAGE GATES
ONLY AND NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE.
MODEL SW470
MEDIUM DUTY SWING GATE OPERATOR
Serial # _______________________
(located on electrical box cover)
Installation Date_________________
2 YEAR WARRANTY
MODEL SW490
HEAVY DUTY SWING GATE OPERATOR
INTENDED FOR PROFESSIONAL INSTALLATION ONLY.
VISIT WWW.LIFTMASTER.COM TO LOCATE A PROFESSIONAL
INSTALLING DEALER IN YOUR AREA.
THIS MANUAL IS TO BE LEFT WITH THE PROPERTY OWNER.