LiftMaster SW470 SW490 GL BOARD Manual - Page 32

Single Phase Wiring Diagram (SW490)

Page 32 highlights

SINGLE PHASE WIRING DIAGRAM (SW490) 1 PHASE POWER IN (GN) GROUND (W) (GN) GL CONTROL BOARD 24 Vac - IN 24 Vac -COMMON J2 PLUG (GY) (Y) SOFT OPEN NC "B" LIMIT CONTACTOR B "A" LIMIT CONTACTOR A SEE NOTE 2 230V ONLY SEE NOTE 5 SEE NOTE 1 (W) PRIMARY R1 (BL) 24V Sec. 115 VOLT MOTOR CONNECTION 115 ONLY SEE NOTE 5 (Y) R2 (BK) B- ALARM ASSY 76-G0564 SEE NOTE 4 (Y) 230 VOLT MOTOR CONNECTION (Y) RPM - IN RPM - SUPPLY RPM GND RADIO COMMAND J2 PLUG SHADOW R3 +24 Vdc CLOSE STOP SOFT OPEN HARD OPEN INT. LOOP OBS. OPEN OBS. CLOSE 24 Vac - COMMON DC - GND LOCK 1 LOCK 2 ALARM 1 ALARM 1 1 2 J4 DUAL GATE RPM SENSOR R4 B+ ALARM ASSY 76-G0564 LEGEND PERMANENT TERMINAL J1 TERMINAL BLOCK TERMINAL BLOCK R 1 R 2 R 3 R 4 24 Vac RADIO SIGNAL NOTES: 1) TRANSFORMER PRIMARY VOLTAGE SAME AS OPERATOR LINE VOLTAGE 24V SECONDARY 60VA. 2) RELAY VOLTAGE SAME AS LINE VOLTAGE. 3) OPTIONAL WIRE HARNESS. 4) (B+) AND (B-) ARE 100dB SAFETY ALARMS. 5) WIRE COLOR: 120V BLACK, 208V RED, 230V ORANGE. APPLICATIONS: CONTROL WIRING TYPE - GL FIELD WIRING & ADJUSTMENTS MODEL TYPES: HORSEPOWER: VOLTAGE/PHASE: SW490 (HSW) 1/2, 3/4 & 1 115V, 208 & 230V - 1 PHASE ONLY 845 Larch Avenue, Elmhurst, IL 60125 DRAWING NUMBER: DATE: 7/29/03 01-G1979-1 REVISION: E ECN: 03-0401 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

32
SINGLE PHASE WIRING DIAGRAM (SW490)
DRAWING NUMBER:
01-G1979-1
DATE:
7/29/03
REVISION:
E
ECN:
03-0401
NOTES:
1)
TRANSFORMER PRIMARY VOLTAGE SAME AS OPERATOR LINE VOLTAGE
24V SECONDARY 60VA.
2)
RELAY VOLTAGE SAME AS LINE VOLTAGE.
3)
OPTIONAL WIRE HARNESS.
4)
(B+) AND (B-) ARE 100dB SAFETY ALARMS.
5)
WIRE COLOR: 120V BLACK, 208V RED, 230V ORANGE.
24V
Sec.
R
R
1
1
R
R
2
2
R
R
3
3
R
R
4
4
J4
1
2
24 Vac - IN
(GY)
(Y)
(W)
(GN)
(GN)
(BL)
(BK)
(Y)
(Y)
(Y)
24 Vac -COMMON
GL CONTROL BOARD
GROUND
1 PHASE
POWER IN
(W)
115 VOLT
MOTOR
CONNECTION
230 VOLT
MOTOR
CONNECTION
SEE NOTE 5
115 ONLY
SEE NOTE 5
SEE NOTE 2
SEE NOTE 1
PRIMARY
230V ONLY
J2 PLUG
J2 PLUG
+24 Vdc
SOFT OPEN
“B” LIMIT
“A” LIMIT
CONTACTOR B
CONTACTOR A
RPM SENSOR
RPM - IN
RPM
GND
RPM - SUPPLY
RADIO COMMAND
SHADOW
CLOSE
STOP
SOFT
OPEN
HARD
OPEN
INT. LOOP
OBS. OPEN
OBS. CLOSE
DC - GND
LOCK 1
LOCK 2
ALARM 1
ALARM 1
ALARM ASSY
76-G0564
24 Vac
RADIO
SIGNAL
DUAL GATE
B+
NC
24 Vac - COMMON
B-
LEGEND
TERMINAL BLOCK
J1 TERMINAL BLOCK
PERMANENT TERMINAL
ALARM ASSY
76-G0564
SEE NOTE 4
R2
R1
R3
R4
APPLICATIONS:
CONTROL WIRING TYPE - GL
FIELD WIRING & ADJUSTMENTS
MODEL TYPES:
SW490 (HSW)
HORSEPOWER:
1/2, 3/4 & 1
VOLTAGE/PHASE:
115V, 208 & 230V - 1 PHASE ONLY
845 Larch Avenue, Elmhurst, IL