Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire. Flexible metal vent • Flexible metal vents are acceptable only if accessible for cleaning, • Flexible metal vent must be fully extended and supported when the dryer is in its final location. • Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. • Do not install flexible metal vent in enclosed walls, ceilings or floors. Elbows 45 ° elbows provide better airflow than 90 ° elbows. WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS, IMPORTANT: Observe all governing codes and ordinances. The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building. If using an existing vent system • Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint, • Replace any plastic or metal foil vent with rigid or flexible heavy metal vent. • Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance. If this is a new vent system Vent material • Use a heavy metal vent. Do not use plastic or metal foil vent. • 4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFF Mventing products are recommended. Good Better Clamps Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape. Clamp Exhaust Recommended hood styles are shown here. B 4" (10.2cm) heavymetal exhaust vent DURASAFF M vent products can be purchased from your dealer or by calling the toll-free number listed on the cover of the Dryer User Instructions. For more information, see the "Assistance or Service" section of the Dryer User Instructions. Rigid metal vent • For best drying performance, rigid metal vents are recommended. • Rigid metal vent is recommended to avoid crushing and kinking. (10.2cm) A. Louvered hood style B. Box hood style The angled hood style (shown here) is acceptable. 4" (10.2 cm)__ 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Fire Hazard
Use a
heavy
metal
vent.
Do not
use a plastic
vent.
Do not
use
a metal
foil
vent.
Flexible
metal
vent
Flexible metal vents are acceptable
only if accessible
for
cleaning,
Flexible metal vent must be fully extended
and supported
when the dryer is in its final location.
Remove excess flexible
metal vent to avoid sagging
and
kinking that may result in reduced
airflow
and poor
performance.
Do not install flexible
metal vent in enclosed
walls, ceilings
or
floors.
Elbows
45 ° elbows
provide better airflow than 90 ° elbows.
Failure
to follow
these
instructions
can result
in
death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED
OUTDOORS,
IMPORTANT:
Observe all governing
codes and ordinances.
The dryer exhaust
must not be connected
into any gas vent,
chimney,
wall, ceiling or a concealed
space of a building.
If
using
an
existing
vent
system
Clean lint from the entire length of the system and make sure
exhaust
hood is not plugged
with lint,
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart.
Modify existing
vent system if
necessary
to achieve the best drying performance.
If this
is a new vent
system
Vent material
Use a heavy metal vent. Do not use plastic
or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps
must be
used. DURASAFF
Mventing
products
are recommended.
4" (10.2cm) heavymetal
exhaust
vent
DURASAFF
M vent products
can be purchased
from your
dealer or by calling the toll-free
number
listed on the cover of
the Dryer User Instructions.
For more information,
see the
"Assistance
or Service"
section of the Dryer User Instructions.
Rigid metal vent
For best drying
performance,
rigid metal vents are
recommended.
Rigid metal vent is recommended
to avoid crushing
and
kinking.
Clamps
Good
Better
Use clamps to seal all joints.
Exhaust vent must not be connected
or secured with screws
or other fastening
devices
that extend
into the interior of the
duct. Do not use duct
tape.
Clamp
Exhaust
Recommended
hood styles are shown here.
B
(10.2cm)
A. Louvered hood
style
B. Box hood style
The angled
hood style (shown here) is acceptable.
4"
(10.2
cm)__