Water Pressure - water filter

Page 4 highlights

Water Pressure A cold water supply with water pressure of between 35 and 120 psi (241 and 827 kPa) is required to operate the water dispenser and ice maker. If you have questions about your water pressure, call a licensed, qualified plumber. Reverse Osmosis Water Supply IMPORTANT: The pressure of the water supply coming out of a reverse osmosis system going to the water inlet valve of the refrigerator needs to be between 35 and 120 psi (241 and 827 kPa). If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis system needs to be a minimum of 40 to 60 psi (276 to 414 kPa). If the water pressure to the reverse osmosis system is less than 40 to 60 psi (276 to 414 kPa): • Check to see whether the sediment filter in the reverse osmosis system is blocked. Replace the filter if necessary. • Allow the storage tank on the reverse osmosis system to refill after heavy usage. • If your refrigerator has a water filter, it may further reduce the water pressure when used in conjunction with a reverse osmosis system. Remove the water filter. See "Water Filtration System." If you have questions about your water pressure, call a licensed, qualified plumber. I Read all directions before you begin. IMPORTANT: If you turn the refrigerator on before the water line is connected, turn the ice maker OFE Connect to Water Line 1. Unplug refrigerator or disconnect power. 2. Turn OFF main water supply. Turn ON nearest faucet long enough to clear line of water. 3. Locate al/2 '' to 11/4`' (12.7 mm to 31.8 mm) vertical cold water pipe near the refrigerator. IMPORTANT: • Make sure it is a cold water pipe. • Horizontal pipe will work, but drill on the top side of the pipe, not the bottom. This will help keep water away from the drill and normal sediment from collecting in the valve. 4. Determine the length of copper tubing you need. Measure from the connection on the rear of the refrigerator to the water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use Y4" (6.35 mm) O.D. (outside diameter) copper tubing. Be sure both ends of copper tubing are cut square. 5. Using a cordless drill, drill a W' hole in the cold water pipe you have selected. C D E F G A. Cold water pipe B. Pipe clamp C. Copper tubing D. Compression nut E. Compression sleeve F. Shutoff valve G. Packing nut 6. Fasten the shutoff valve to the cold water pipe with the pipe clamp. Be sure the outlet end is solidly in the 1/4' drilled hole in the water pipe and that the washer is under the pipe clamp. Tighten the packing nut. Tighten the pipe clamp screws slowly and evenly so washer makes a watertight seal. Do not overtighten or you may crush the copper tubing. 7. Slip the compression sleeve and compression nut on the copper tubing as shown. Insert the end of the tubing into the outlet end squarely as far as it will go. Screw compression nut onto outlet end with adjustable wrench. Do not overtighten. 8. Place the free end of the tubing in a container or sink, and turn ON the main water supply. Flush the tubing until water is clear. Turn OFF the shutoff valve on the water pipe. Coil the copper tubing. Connect to Refrigerator 1. Remove plastic cap from water supply connection. Place brass nut and compression sleeve on copper tube end as shown. I A b° A. Brass nut B. Compression sleeve 2. Place end of copper tubing into plastic water valve supply line. Slide the brass nut over the sleeve and screw the nut into supply line. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Water Pressure
A cold water supply
with water pressure
of between 35 and
120 psi (241 and 827 kPa) is required to operate
the water
dispenser
and ice maker. If you have questions
about your water
pressure,
call a licensed,
qualified
plumber.
Reverse
Osmosis
Water
Supply
IMPORTANT:
The pressure
of the water supply
coming
out of a
reverse osmosis system
going to the water
inlet valve of the
refrigerator
needs to be between 35 and 120 psi (241 and
827 kPa).
If a reverse osmosis water filtration
system
is connected
to your
cold water supply, the water
pressure to the reverse osmosis
system needs to be a minimum
of 40 to 60 psi (276 to 414 kPa).
If the water
pressure to the reverse osmosis
system is less than
40 to 60 psi (276 to 414 kPa):
Check to see whether
the sediment
filter
in the reverse
osmosis
system
is blocked.
Replace the filter if necessary.
Allow the storage tank on the reverse osmosis
system to refill
after heavy usage.
If your refrigerator
has a water filter, it may further
reduce the
water pressure
when used in conjunction
with a reverse
osmosis
system.
Remove the water filter. See "Water
Filtration
System."
If you have questions
about your water
pressure, call a licensed,
qualified
plumber.
I)()
_
...........
'<
Read all directions
before you begin.
IMPORTANT:
If you turn the refrigerator
on before the water line
is connected,
turn the ice maker
OFE
Connect
to Water
Line
1.
Unplug
refrigerator
or disconnect
power.
2.
Turn OFF main water supply. Turn ON nearest faucet
long
enough to clear line of water.
3.
Locate
al/2 '' to 11/4
`' (12.7 mm to 31.8 mm) vertical cold water
pipe near the refrigerator.
IMPORTANT:
4.
Make sure it is a cold water pipe.
Horizontal
pipe will work,
but drill on the top side of the
pipe, not the bottom.
This will help keep water away from
the drill and normal sediment
from collecting
in the valve.
Determine
the length of copper tubing
you need.
Measure
from the connection
on the rear of the refrigerator
to the
water pipe. Add 7 ft (2.1 m) to allow for cleaning.
Use
Y4"
(6.35 mm) O.D. (outside
diameter)
copper tubing.
Be sure
both ends of copper
tubing
are cut square.
5.
Using a cordless
drill, drill a
W'
hole in the cold water pipe you
have selected.
C
D
E
F
G
A. Cold water pipe
B. Pipe clamp
C. Copper
tubing
D. Compression
nut
E. Compression
sleeve
F. Shutoff
valve
G. Packing
nut
6.
Fasten the shutoff
valve to the cold water pipe with the pipe
clamp.
Be sure the outlet end is solidly
in the 1/4' drilled hole
in the water pipe and that the washer
is under the pipe clamp.
Tighten the packing
nut. Tighten
the pipe clamp screws
slowly
and evenly so washer
makes a watertight
seal. Do not
overtighten
or you may crush the copper
tubing.
7.
Slip the compression
sleeve and compression
nut on the
copper
tubing
as shown.
Insert the end of the tubing
into the
outlet end squarely as far as it will go. Screw compression
nut
onto outlet end with
adjustable
wrench.
Do not overtighten.
8.
Place the free end of the tubing
in a container
or sink, and
turn ON the main water supply. Flush the tubing
until water is
clear. Turn OFF the shutoff
valve on the water
pipe. Coil the
copper
tubing.
Connect
to Refrigerator
1.
Remove
plastic
cap from water supply
connection.
Place
brass nut and compression
sleeve on copper tube end as
shown.
I
A
b
°
A. Brass nut
B. Compression
sleeve
2.
Place end of copper
tubing
into plastic
water valve supply
line. Slide the brass nut over the sleeve and screw the nut into
supply
line.