Panasonic AW-RP150GJ AW-RP150 Interface Specifications - Page 17
Tracing memory Only supported by the AW-RP120 and AW-RP150
View all Panasonic AW-RP150GJ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Remote Camera Controller Interface Specifications Tracing memory (Only supported by the AW-RP120 and AW-RP150) These commands enable the tracing memory to be placed in the standby, play or stop status for the camera/pan-tilt head selected. Command name TMEM standby control command TMEM play control command TMEM stop control command Category Control Response Control Response Control Response Table 6.1.3. Tracing memory ControlMeth od Serial IP Command Data value ○ ○ XTM:02:[Data] 001 ~ ○ - XTM:02:[Data] 10 ○ ○ XTM:01:[Data] 000 ○ - XTM:01:[Data] ○ ○ XTM:00:[Data] 001 ~ ○ - XTM:00:[Data] 010 ~ Setting TracingNo1 TracingNo100 Play Stop Remarks Only for AW-RP120 and AW-RP150. Only for AW-RP120 and AW-RP150. Only for AW-RP120 and AW-RP150. Example of use) ・TMEM standby: TracingNo1 [Control] PC → AW-RP120 http://192.168.0.10/cgi-bin/aw_cam?cmd=XTM:02:001&res=1 [Response] AW-RP120 → PC HTTP/1.1 200 OK © Panasonic Corporation 2020 All Rights Reserved. - 17 -