Panasonic AW-RP150GJ AW-RP150 Interface Specifications - Page 20

Error return

Page 20 highlights

Remote Camera Controller Interface Specifications 7. Error return There are three kinds of errors - ER1, ER2 and ER3 as described below - which are generated in response to the controller control commands in a network connection. In a serial connection, the same command as the request is returned as the response to the control command. 7.1. In case of AW-RP120, AW-RP150 and AW-RP60 ① ER1 (unsupported command) This error is generated when a command which is not supported by the controller has been received. Example) When the non-existent "XF" command is executed for the controller. PC Controller http://192.168.0.10/cgi-bin/aw_cam?cmd= XF&res=1 HTTP/1.1 200 OK ER1: Fig.7.1-1 Error (ER1) ② ER2 (busy status) Error generated when the controller is in the Busy status such as when group switching is in progress. PC Controller http://192.168.0.10/cgi-bin/aw_cam?cmd= XPT:1&res=1 HTTP/1.1 200 OK ER2:XPT Group switching in progress Fig.7.1-2 Error (ER2) © Panasonic Corporation 2020 All Rights Reserved. - 20 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Remote Camera Controller
Interface Specifications
©
Panasonic Corporation 2020 All Rights Reserved.
- 20 -
7.
Error return
There are three kinds of errors — ER1, ER2 and ER3 as described below — which are generated in
response to the controller control commands in a network connection. In a serial connection, the
same command as the request is returned as the response to the control command.
7.1.
In case of AW-RP120, AW-RP150 and AW-RP60
ER1 (unsupported command)
This error is generated when a command which is not supported by the controller has been
received.
Example)
When the non-existent “XF” command is executed for the controller.
Fig.7.1-1
Error (ER1)
ER2 (busy status)
Error generated when the controller is in the Busy status such as when group switching is in
progress.
Fig.7.1-2
Error (ER2)
XF
&res=1
HTTP/1.1
200 OK ER1:
PC
Controller
XPT:1
&res=1
HTTP/1.1
200 OK
ER2:XPT
PC
Group switching
in progress
Controller