Page 20 highlights
Remote Camera Controller Interface Specifications 7. Error return There are three kinds of errors - ER1, ER2 and ER3 as described below - which are generated in response to the controller control commands in a network connection. In a serial connection, the same command as the request is returned as the response to the control command. 7.1. In case of AW-RP120, AW-RP150 and AW-RP60 ① ER1 (unsupported command) This error is generated when a command which is not supported by the controller has been received. Example) When the non-existent "XF" command is executed for the controller. PC Controller http://192.168.0.10/cgi-bin/aw_cam?cmd= XF&res=1 HTTP/1.1 200 OK ER1: Fig.7.1-1 Error (ER1) ② ER2 (busy status) Error generated when the controller is in the Busy status such as when group switching is in progress. PC Controller http://192.168.0.10/cgi-bin/aw_cam?cmd= XPT:1&res=1 HTTP/1.1 200 OK ER2:XPT Group switching in progress Fig.7.1-2 Error (ER2) © Panasonic Corporation 2020 All Rights Reserved. - 20 -