Panasonic BT-LH910GJ Operating Instructions - Page 51

Control, Hours Meter, Description, Local Enable, Operation

Page 51 highlights

Main Menu (continued) CONTROL Sub menu CONTROL Settings LOCAL REMOTE LOCAL ENABLE *2 DISABLE INPUT The underlined values are factory preset setting values. Description Selects operation. (with control clock) Enables front panel operation Enables remote operation (front panel operation is locked) *1 Selects the disabled operation on the front panel when selecting "REMOTE" under "CONTROL". Disables all front panel operations. All controls except [INPUT SELECT] and the volume knob are disabled. *1 The menu can be displayed when the lock is engaged. Only "CONTROL/LOCAL ENABLE" menu items are available when the lock is engaged. The picture adjusting knob is disabled when the lock is engaged. The FUNCTION buttons cannot be operated when the lock is engaged. The "LOCAL ENABLE" setting determines operations in lock mode. The key mark is displayed during lock engagement. [MAIN MENU] Key mark 2D/3D ASSIST 2D MARKER *2 Only availVaIbDlEeOwChOeNnF"IGREMOTE" is selected under "CONTROL." SYSTEM CONFIG VF CONFIG FUNCTION GPI HOURS MEIDNTIPSEUPRLTASYESLEETCUTP CONTROL Sub menu HOURMESTEeRttings Description OPERATION XXXXXXh *1 Displays the number of hours it has been on. LCD XXXXXXh *1 Displays the number of hours that the backlight has been on. *1 "XXXXXX" indicates up to 262,800 hours (approx. 30 years). "OVER" is indicated when the number of hours is 262,800 or higher. 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

51
Main Menu
(continued)
CONTROL
The underlined values are factory preset setting values.
Sub menu
Settings
Description
CONTROL
LOCAL
REMOTE
Selects operation. (with control clock)
<LOCAL>
Enables front panel operation
<REMOTE>
Enables remote operation (front panel
operation is locked)
*
1
LOCAL ENABLE
*
2
DISABLE
INPUT
Selects the disabled operation on the front panel when
selecting “REMOTE” under “CONTROL”.
<DISABLE>
Disables all front panel operations.
<INPUT>
All controls except [INPUT SELECT] and the
volume knob are disabled.
The menu can be displayed when the lock is engaged.
*
1
Only “CONTROL/LOCAL ENABLE” menu items are available when the lock is engaged.
The picture adjusting knob is disabled when the lock is engaged.
The FUNCTION buttons cannot be operated when the lock is engaged.
The “LOCAL ENABLE” setting determines operations in lock mode.
The key mark is displayed during lock engagement.
[MAIN MENU]
2D/3D ASSIST
MARKER
2D
Key mark
Only available when “REMOTE” is selected under “CONTROL.”
*
2
HOURS METER
Sub menu
Settings
Description
OPERATION
XXXXXXh
*
1
Displays the number of hours it has been on.
LCD
XXXXXXh
*
1
Displays the number of hours that the backlight has been on.
“XXXXXX” indicates up to 262,800 hours (approx. 30 years). “OVER” is indicated when the number of
*
1