SPECIFICATIONS AND DIMENSIONS ATMOSPHERIC UNITS B D C INDOOR DRAFTHOOD 38" 13-1/4" GAS CONNECTION Amp Draw 120 Volt 240 Volt AFT 4 2 CL FLUE 10" J* 4-3/8" (3-3/8" ASME) 8-7/8" (6-5/8" ASME) 32-11/16" ELECTRICAL CONNECTION 26-5/8" (28-5/8" ASME) 40" STACKLESS OUTDOOR TOP A 28" Shipping Weights (lbs) Heater Model R206A BTUH Input (000) 199.5 (A) Cabinet Width 20" (B) Flue Dia. 6" (C) (D) Indoor Drafthood 61-5/8" 10.0" (J) Min. 11-3/4" Gas Conn. Standard ASME Heater Heater Water w/Stackless w/Stackless Conn. Top Top Indoor Drafthood 3/4" 2" 187 206 14 R266A 266.0 23" 7" 62" 11.5" 11" 3/4" 2" 210 229 16 R336A 332.5 26" 8" 63" 13.0" 10-5/8" 3/4" 2" 230 249 19 R406A 399.0 29" 9" 64-9/16" 14.5" 12-1/8" 3/4" 2" 249 268 21 Designation for an AFT heater using propane gas is "EP"; an AFT heater using natural gas is "EN". Designation for a Millivolt heater using propane gas is "MP"; a Millivolt heater using natural gas is "MN". Prefix "C" is for cast iron (ASME) headers; "P" is for plastic (polymer) headers. Suffix "X" is for cupro-nickel tubing; "C" is for copper tubing. EXAMPLE: P-R406A-EN-X = Plastic headers, 406 model size, AFT, natural gas, cupro-nickel. Reduce input 4% for each 1000 ft above sea level when installed above 2000 ft elevation. For Canada, no de-rating is required for elevations up to 4500 ft Plastic (polymer) headers cannot be used for ASME installations. *Note: For outdoor stack, use J dimension in the table above for appropriate size PLUS six (6) inches. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

16
SPECIFICATIONS AND DIMENSIONS
Heater
Model
BTUH
Input
(000)
(A)
Cabinet
Width
(B)
Flue
Dia.
(C)
Indoor
Drafthood
(D)
(J)
Min.
Gas
Conn.
Water
Conn.
Shipping Weights (lbs)
Standard
Heater
w/Stackless
Top
ASME
Heater
w/Stackless
Top
Indoor
Draft-
hood
R206A
199.5
20”
6”
61-5/8”
10.0”
11-3/4”
3/4”
2”
187
206
14
R266A
266.0
23”
7”
62”
11.5”
11”
3/4”
2”
210
229
16
R336A
332.5
26”
8”
63”
13.0”
10-5/8”
3/4”
2”
230
249
19
R406A
399.0
29”
9”
64-9/16”
14.5”
12-1/8”
3/4”
2”
249
268
21
ATMOSPHERIC UNITS
Designation for an AFT heater using propane gas is “EP”; an AFT heater using natural gas is “EN”.
Designation for a Millivolt heater using propane gas is “MP”; a Millivolt heater using natural gas is “MN”.
Prefix “C” is for cast iron (ASME) headers; “P” is for plastic (polymer) headers.
Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing.
EXAMPLE:
P-R406A-EN-X
= Plastic headers, 406 model size, AFT, natural gas, cupro-nickel.
Reduce input 4% for each 1000 ft above sea level when installed above 2000 ft elevation.
For Canada, no de-rating is required for elevations up to 4500 ft
Plastic (polymer) headers cannot be used for ASME installations.
*Note: For outdoor stack, use J dimension in the table above for appropriate size PLUS six (6) inches.
B
C
INDOOR
DRAFTHOOD
38"
13-1/4"
GAS
CONNECTION
J
A
26-5/8"
(28-5/8" ASME)
32-11/16"
ELECTRICAL
CONNECTION
40"
STACKLESS
OUTDOOR TOP
28"
4-3/8"
(3-3/8" ASME)
8-7/8"
(6-5/8" ASME)
D
10"
FLUE
L
C
Amp Draw
120 Volt
240 Volt
AFT
4
2
*