Rheem P-M406 Operating Instructions - Page 34

Spa Max Temp - Spa Set Point Maximum

Page 34 highlights

Program Button 1) Remove the four screws holding the control cover, and swing the panel down so the back side of the board is visible (see page 31). Locate the Program Mode button (marked as SW1) as shown on page 33. Press and hold the button (5-7 seconds) until Set Factory Defaults appears on the display. Release the program button. Fahrenheit or Celsius Refer to step one above to access the program screen. Press the Mode button until Fahrenheit or Celsius appears on the digital display. The digital display is capable of displaying Celsius as well as Fahrenheit temperatures. The UP or DOWN buttons will select Fahrenheit or Celsius on the temperature display. Choose the desired temperature scale. 2) Press the Mode button sequentially until the desired program event is reached. There are 5 different events that can be programmed. They appear in the sequence listed below: Resets board to factory default settings. Resets faults in the History File. Change from Fahrenheit to Celsius. SPA setpoint maximum adjustment. POOL setpoint maximum adjustment. Set Factory Defaults Refer to step one above to access the program screen. Set Factory Defaults should appear on the screen. If it does not, press the Mode button until Set Factory Defaults appears on the digital display. Press and hold both UP and DOWN buttons for 5-7 seconds until Defaults Set appears. This operation resets the operating program to its factory default values. Both the POOL and SPA setpoints will revert to 65°F (18.5°C) and both POOL and SPA maximum temperature settings will be 104°F (40.0°C). The Control Lockout PIN will be cleared and the control will resume normal operation. Clear Faults Refer to step one above to access the program screen. Press the Mode button until Clear Faults appears on the digital display. Press and hold both UP and DOWN buttons for 5-7 seconds until Faults Cleared appears. This operation resets the Fault History file to "0" and clears all the stored faults. Spa Max Temp - Spa Set Point Maximum Adjustment Refer to step one above to access the program screen. Press the Mode button until Spa Max Temp appears on the digital display. Using the UP and DOWN buttons will change the Maximum Temperature Setting to your desired value. The control can be set for a maximum of 107°F. Pool Max Temp - Pool Set Point Maximum Adjustment Refer to step one above access into the program screen. Press the Mode button until Pool Max Temp appears on the digital display. Using the UP and DOWN buttons will change the Maximum Temperature Setting to your desired value. The control can be set for a maximum of 107°F. Control Lockout The heater is equipped with a Control Lockout feature to prevent unauthorized tampering or adjustment of the control settings. To lock out the controls, press the DOWN button and Mode button for 5 seconds. Choose a three digit PIN, using the UP and DOWN buttons to select the digits and the Mode button to lock in selections. Confirm your selection and record your PIN. To unlock the controls, press any button to bring up the Enter PIN menu. Enter the PIN that was used to lock the control. Note that power cycling will not clear the lockout. Successfully unlocking the control will display "Lockout Cleared." Failure to enter the correct PIN will display "Invalid PIN." In the event that the user-selected PIN is lost or does not clear the Control Lockout, use the Program Button to Set Factory Defaults. This will clear the PIN and allow normal operation and selection of a new PIN if desired. See the Program Button directions on this page for details. NOTE: Both the POOL and SPA setpoints will revert back to 65°F (18.5°C) and the POOL and SPA maximum temperature settings will be 104°F (40.0°C). These setpoints will need to be readjusted to desired settings. 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

34
Resets board to factory default
settings.
Resets faults in the History File.
Change from Fahrenheit to
Celsius.
SPA setpoint maximum adjustment.
POOL setpoint maximum
adjustment.
Set Factory Defaults
Refer to step one above to access the program
screen.
Set Factory Defaults
should appear on the
screen. If it does not, press the
Mode
button until
Set
Factory Defaults
appears on the digital display.
Press and hold both UP and DOWN buttons for 5-7
seconds until
Defaults Set
appears. This operation
resets the operating program to its factory default val-
ues. Both the POOL and SPA setpoints will revert to
65°F (18.5°C) and both POOL and SPA maximum
temperature settings will be 104°F (40.0°C). The
Control Lockout PIN will be cleared and the control will
resume normal operation.
Clear Faults
Refer to step one above to access the program
screen. Press the
Mode
button until
Clear Faults
appears on the digital display. Press and hold both UP
and DOWN buttons for 5-7 seconds until
Faults
Cleared
appears. This operation resets the Fault
History file to “0” and clears all the stored faults.
Program Button
1)
Remove the four screws holding the control cover,
and swing the panel down so the back side of the
board is visible (see page 31). Locate the Program
Mode button (marked as SW1) as shown on page
33. Press and hold the button (5-7 seconds) until
Set Factory Defaults
appears on the display.
Release the program button.
2) Press the
Mode
button sequentially until the
desired program event is reached. There are 5 dif-
ferent events that can be programmed. They
appear in the sequence listed below:
Fahrenheit or Celsius
Refer to step one above to access the program
screen. Press the
Mode
button until
Fahrenheit
or
Celsius
appears on the digital display. The digital dis-
play is capable of displaying Celsius as well as
Fahrenheit temperatures. The UP or DOWN buttons
will select
Fahrenheit
or
Celsius
on the temperature
display. Choose the desired temperature scale.
Spa Max Temp – Spa Set Point Maximum
Adjustment
Refer to step one above to access the program
screen. Press the
Mode
button until
Spa Max Temp
appears on the digital display. Using the UP and
DOWN buttons will change the Maximum Temperature
Setting to your desired value. The control can be set
for a maximum of 107°F.
Pool Max Temp – Pool Set Point Maximum
Adjustment
Refer to step one above access into the program
screen. Press the
Mode
button until
Pool Max Temp
appears on the digital display. Using the UP and
DOWN buttons will change the Maximum Temperature
Setting to your desired value. The control can be set
for a maximum of 107°F.
Control Lockout
The heater is equipped with a Control Lockout feature
to prevent unauthorized tampering or adjustment of
the control settings. To lock out the controls, press the
DOWN button and
Mode
button for 5 seconds.
Choose a three digit PIN, using the UP and DOWN
buttons to select the digits and the
Mode
button to lock
in selections. Confirm your selection and record your
PIN.
To unlock the controls, press any button to bring up the
Enter PIN
menu. Enter the PIN that was used to lock
the control. Note that power cycling will
not
clear the
lockout. Successfully unlocking the control will display
“Lockout Cleared.” Failure to enter the correct PIN will
display “Invalid PIN.”
In the event that the user-selected PIN is lost or does
not clear the Control Lockout, use the Program Button
to
Set Factory Defaults
. This will clear the PIN and
allow normal operation and selection of a new PIN if
desired. See the
Program Button
directions on this
page for details.
NOTE:
Both the POOL and SPA setpoints will revert
back to 65°F (18.5°C) and the POOL and SPA maxi-
mum temperature settings will be 104°F (40.0°C).
These setpoints will need to be readjusted to desired