Installation Installation STEP 3 Connect the electrical wiring (for electric models) Before connecting the electrical wiring, make sure you have read the "Electrical requirements" section on page 18. 3-wire system D A B C L2 L1 E A. External ground connector B. Neutral grounding wire (white) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. 3/4" (1.9 cm) UL-listed strain relief 1. Loosen or remove the screws from the center terminal block. 2. Connect the neutral wire (white or center wire) of the power cable to the center, silver-colored terminal screw of the terminal block. Tighten the screws. 3. Connect the other wires to outer terminal block screws. Tighten the screws. 4. Tighten the strain relief screws. 5. Insert the terminal block cover into the rear panel of the dryer. Then, secure the cover with a hold-down screw. CAUTION • To convert from the 4-wire system to 3-wire system, connect the ground strap to the terminal block support to ground the dryer frame to the neutral conductor. • Ring-type terminals are recommended. If using strap terminals, make sure they are tightened. • Before Installing the Dryer, confirm 240 V is present between L1 and L2 at the power receptacle. If the Voltage is low, it may not dry properly. Review the "Electrical requirements" section on page 18 if needed. 24 English Untitled-10 24 2020-07-14 3:22:15