Samsung DVG54R7600V/A3 User Manual - Page 24

wire system, Electrical, requirements, Installation

Page 24 highlights

Installation Installation 4-wire system F D A B C L2 L1 E A. External ground connector B. Neutral grounding wire (white) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾" (1.9 cm) UL-listed strain relief F. Neutral wire (white or center wire) 1. Remove the external ground connector's screw and connect the ground wire (green or unwrapped) of the power cable to the screw. CAUTION - To connect the ground wire to the neutral position without through contact A (cabinet ground), contact a technician. This is not user serviceable. - Ring-type terminals are recommended. If using strap terminals, make sure they are tightened. 2. Loosen or remove the screws from the center terminal block. 3. Connect the neutral wire (white or center wire) and ground wire (white) to the center screw of the terminal block. Tighten the screw. 4. Connect the other wires to the outer terminal block screws. Tighten the screws. 5. Tighten the strain relief screws. 6. Insert the tab of the terminal block cover into the rear slot of the dryer. Secure the cover with a hold-down screw. CAUTION Before Installing the Dryer, confirm 240 V is present between L1 and L2 at the power receptacle. If the Voltage is low, it may not dry properly. Review the "Electrical requirements" section on page 17 if needed. 24 English Untitled-18 24 2020-07-14 3:40:07

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

Installation
English
24
Installation
4-wire system
F
A
B
C
L2
L1
D
E
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
¾” (1.9 cm) UL-listed strain relief
F.
Neutral wire (white or center wire)
1.
Remove the external ground
connector’s screw and connect the
ground wire (green or unwrapped) of
the power cable to the screw.
CAUTION
-
To connect the ground wire to the
neutral position without through
contact A (cabinet ground), contact
a technician. This is not user
serviceable.
- Ring-type terminals are
recommended. If using strap
terminals, make sure they are
tightened.
2.
Loosen or remove the screws from the
center terminal block.
3.
Connect the neutral wire (white or
center wire) and ground wire (white) to
the center screw of the terminal block.
Tighten the screw.
4.
Connect the other wires to the outer
terminal block screws. Tighten the
screws.
5.
Tighten the strain relief screws.
6.
Insert the tab of the terminal block
cover into the rear slot of the dryer.
Secure the cover with a hold-down
screw.
CAUTION
Before Installing the Dryer, confirm 240 V is present between L1 and L2 at the power
receptacle. If the Voltage is low, it may not dry properly. Review the “
Electrical
requirements
” section on page
17
if needed.
Untitled-18
24
2020-07-14
°° 3:40:07