ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless testing requires power. NO Error Code Diagnostic Code Error Image Description Corrective Action 11 tE tE Abnormal high/low temperature or resistance (Thermal sensor or PBA resistance). Go to " Board Input Test" and check Water Temperature. Check loose or pinched wires. Replace PCB or thermistor. 12 3E MICOM is attempting to drive the motor but is not getting any response signals Evaluate wire harness for loose or 3E from the hall sensor. Visual check shows unhooked connections. Go to " motor is not running. (Locked, Defective Quick Test Mode" and test Motor. Hall Sensor or Overload) 13 Hr Hr This error code appears when the heater is 96°C or above. Replace PCB 14 nF1 15 suds 16 AE nF1 suds AE This error code appears when the water temperature is 50°C or above Please connect the hot/cold water for 8 seconds or longer in the Wool hose connection correctly. and Delicate course. Suds is detected during the washing session. ("SUdS" is not an error. If the washer is in suds period, "SUdS" will Guide a user to reduce amount of detergent usage. light up instead of remaining time.) Communication error between SUB Check Main PBA, SUB PBA & Wire- PBA and MAIN PBA harness. Replace PCB 17 SF SF System Error Replace PCB 18 2E 2E Voltage for motor control bus is over or under specified limit. Replace PCB 3 WF405ATP-03144A_EN.indd 3 2012-03-02 �� 9:28:47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

ALIGNMENT AND ADJUSTMENTS
3
NO
Error
Code
Diagnostic Code
Error Image
Description
Corrective Action
11
tE
tE
Abnormal high/low temperature or
resistance (Thermal sensor or PBA
resistance).
Go to “ Board Input Test” and check
Water Temperature. Check loose
or pinched wires. Replace PCB or
thermistor.
12
3E
3E
MICOM is attempting to drive the motor
but is not getting any response signals
from the hall sensor. Visual check shows
motor is not running. (Locked, Defective
Hall Sensor or Overload)
Evaluate wire harness for loose or
unhooked connections. Go to “
Quick Test Mode” and test Motor.
13
Hr
Hr
This error code appears when the
heater is 96°C or above.
Replace PCB
14
nF1
nF1
This error code appears when the
water temperature is 50°C or above
for 8 seconds or longer in the Wool
and Delicate course.
Please connect the hot/cold water
hose connection correctly.
15
suds
suds
Suds is detected during the washing
session. (“SUdS” is not an error. If the
washer is in suds period, “SUdS” will
light up instead of remaining time.)
Guide a user to reduce
amount of
detergent usage.
16
AE
AE
Communication error between SUB
PBA and MAIN PBA
Check Main PBA, SUB PBA & Wire-
harness. Replace PCB
17
SF
SF
System Error
Replace PCB
18
2E
2E
Voltage for motor control bus is
over or under specified limit.
Replace PCB
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
WARNING
WF405ATP-03144A_EN.indd
3
2012-03-02
�� 9:28:47