PLC-HP7000L Expand Serial Command Functional Specifications 9.11 Other Status Read Commands 9.11.1 CR_STATUS Command COMMAND "CR_STATUS" [CR] Detail Get operating status of Projector Same as "CR0" in basic command except error code follows it. Acceptable "000_%1" [CR] Response "00" = Power ON "80" = Standby "40" = Countdown in process "20" = Cooling Down in process "10" = Power Failure "28" = Cooling Down in process due to abnormal temperature "88" =Standby after Cooling Down due to abnormal temperature %1 "24" = Power Save/Cooling Down in process "04" = Power Save "21" = Cooling Down in process after turned Off due to lamp failure "81"= Standby after Cooling Down due to lamp failure "2C" = Cooling Down in process after Power Off due to Shutter management "8C"= Standby after Cooling Down due to Shutter management Unacceptable "Error Code" [CR] 9.11.2 CR_SIGNAL Command Command "CR_SIGNAL" [CR] Details Get status whether there is any signal or not. Acceptable "000_%1" [CR] Response %1 "ON There is signal "OFF There is no signal Unacceptable "Error Code" [CR] 9.11.3 CR_VMUTE Command Command "CR_VMUTE" [CR] Details Get setting status of Video Mute. Acceptable "000_%1" [CR] Response %1 "ON Set Video Mute (Shutter CLOSE) "OFF Cancel Video Mute (Shutter OPEN) Unacceptable "Error Code" [CR] 9.11.4 CR_FREEZE Command Command "CR_FREEZE" [CR] Details Get setting status of Freeze. Acceptable "000_%1" [CR] Response %1 "ON Freeze is enabled "OFF Freeze is disabled Unacceptable "Error Code" [CR] 92/94

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

PLC-HP7000L Expand Serial Command Functional Specifications
92/94
9.11 Other Status Read Commands
9.11.1 CR_STATUS Command
COMMAND
“CR_STATUS” [CR]
Detail
Get operating status of Projector
Same as “CR0” in basic command except error code follows it.
Acceptable
“000_%1” [CR]
%1
“00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to abnormal temperature
“88” =Standby after Cooling Down due to abnormal
temperature
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after turned Off due to lamp
failure
“81”
Standby after Cooling Down due to lamp failure
“2C” = Cooling Down in process after Power Off due to
Shutter management
“8C”= Standby after Cooling Down due to Shutter
management
Response
Unacceptable
“Error Code” [CR]
9.11.2 CR_SIGNAL Command
Command
“CR_SIGNAL” [CR]
Details
Get status whether there is any signal or not.
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- There is signal
“OFF” ------------------------- There is no signal
Response
Unacceptable
“Error Code” [CR]
9.11.3 CR_VMUTE Command
Command
“CR_VMUTE” [CR]
Details
Get setting status of Video Mute.
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- Set Video Mute (Shutter CLOSE)
“OFF” ------------------------ Cancel Video Mute (Shutter OPEN)
Response
Unacceptable
“Error Code” [CR]
9.11.4 CR_FREEZE Command
Command
“CR_FREEZE” [CR]
Details
Get setting status of Freeze.
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------------- Freeze is enabled
“OFF” -------------------------- Freeze is disabled
Response
Unacceptable