Seagate 15K.3 ST373453FC Model Product Manual PDF - Page 52

Cheetah 15K.3 FC Product Manual, Rev. D, Fibre Channel fabric login

Page 52 highlights

42 Cheetah 15K.3 FC Product Manual, Rev. D 9.1.8 Fibre Channel fabric login Table 11 lists the fabric login payload from the drive. Table 11: Fabric Login (FLOGI) payload Bytes 0-15 04 00 00 00 09 09 00 00 08 00 08 40 00 00 00 00 Common 16-31 00 00 02 F4 2P 00 00 CC CC UI UI UI 02 00 00 CC 32-35 CC UI UI UI 36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1 48-51 00 00 00 00 52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2 64-67 00 00 00 00 68-79 80 00 00 00 00 00 08 40 00 00 00 00 Class 3 80-83 00 00 00 00 84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved 96-99 00 00 00 00 100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor - 112-115 00 00 00 00 Version CC Bytes (23 and 24) and (31 and 32) are currently factory set to 04 CF respectively (subject to change). UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name fields. P Port identifier field. 1 FLOGI originated on Port A. 2 FLOGI originated on Port B.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

42
Cheetah 15K.3 FC Product Manual, Rev. D
9.1.8
Fibre Channel fabric login
Table 11 lists the fabric login payload from the drive.
Table 11:
Fabric Login (FLOGI) payload
Bytes
0-15
04
00
00
00
09
09
00
00
08
00
08
40
00
00
00
00
Common
16-31
00
00
02
F4
2P
00
00
CC
CC
UI
UI
UI
02
00
00
CC
32-35
CC
UI
UI
UI
36-47
00
00
00
00
00
00
00
00
00
00
00
00
Class 1
48-51
00
00
00
00
52-63
00
00
00
00
00
00
00
00
00
00
00
00
Class 2
64-67
00
00
00
00
68-79
80
00
00
00
00
00
08
40
00
00
00
00
Class 3
80-83
00
00
00
00
84-95
00
00
00
00
00
00
00
00
00
00
00
00
Reserved
96-99
00
00
00
00
100-111
00
00
00
00
00
00
00
00
00
00
00
00
Vendor -
112-115
00
00
00
00
Version
CC
Bytes (23 and 24) and (31 and 32) are currently factory set to 04 CF respectively (subject to change).
UI
Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name
fields.
P
Port identifier field.
1
FLOGI originated on Port A.
2
FLOGI originated on Port B.