Sharp MS722 Service Manual - Page 15

TEST-REC Mode, NORMAL Mode, Digital input display Mode Din Mon, Error data display Mode, Explanation

Page 15 highlights

MD-MS722/C/W/MS721W •Whenever the DISP button is pressed in the continuous playback mode, the indication changes as follows. * Pit section Continuous playback (SUBQ address indication) [ S Q ] | Continuous playback (C1 error indication) [ C E ] | Continuous playback (SUBQ address indication) [ S Q ] * Groove section Continuous playback (ADIP address indication) [ A P ] | Continuous playback (C1 error indication) [ C E ] | Continuous playback (ADIP error indication) [ A E ] | Continuous playback (ADIP address indication) [ A P ] 8. TEST-REC Mode • When the STOP button is pressed while the TEST-REC menu appears, or in the TEST-REC mode or continuous record mode, the mode changes to the TEST mode stop state. • When the PLAY button is pressed while the TEST-REC menu appears, the continuous record is initiated from the current pickup position. • Whenever the DISP button is pressed in the TEST-REC mode, the address changes as follows. 0050 - 03C0 - 0700 - 08A0 - 0050 - • Whenever the BASS button is pressed in the TEST-REC mode, the digit which is changed by the SKIP UP/DOWN button changes as follows. 0050 - 0050 - 0050 - 0050 - 0050 - • When the SKIP UP button s pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to +1h.(0 to F) • When the SKIP DOWN button is pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to -1h. (0 to F) * When the SKIP UP/DOWN button is held down, the setting changes continuously, one cycle being 100 ms. • When the VOL UP/DOWN button is pressed in the TEST-REC mode or continuous record mode, the laser record power changes. (Servo gain changes also according to record power.) * After the laser record power is indicated for one second, the address indication is restored. [ RPW ] • : Address • : Laser power cord • Operation is disabled if the premastered disc or disc is in miserase-protected state. 9. NORMAL Mode • When the STOP button is pressed while the NORMAl menu appears, the mode changes to the TEST mode stop state. • Indication during operation Indication of memory capacity on main unit LCD [ ] + Level meter : Internal mode : Address (Cluster section) : Address (Sector section) • Selection of sound volume, BASS, etc. is possible (without indication) • Recording is also possible. 10. Digital input display Mode (Din Mon) • When the STOP button is pressed while the digital input indication menu appears or during digital input information indication, the mode changes to the TEST mode stop state. • In case of analog input or digital input unlocking the indication data is _. 11. Error data display Mode • Reversing when SKIP DOWN button is pressed • When the STOP button is pressed while the error data indication menu appears or during error data indication, the mode changes to the TEST mode stop state. • Error data 0 is the latest error. • Error which occurred in the TEST mode is also stored in the memory. • When the DISP button is pressed while the error data indication menu appears, the error data is initialized. [ C L E A R _ ] • : Error Code Explanation of error history code 12h : RF side FG, TG, and TCRS adjustment termination failure 13h : Adjustment servo retraction excessive retrial 16h : C. IN detection time-over 17h : A, B, E, F, and TCRSO offset measurement value out of tolerable range 21h : Focus retraction completion allowable time-over 23h : Track search completion allowable time-over 24h : Disc linear speed measurement failure 32h : P-TOC read failure 42h : U-TOC read failure 44h : U-TOC write data write disabled/read check error 52h : SD write data write disabled 71h : Pickup position initialization time-over 72h : EEPROM data read check sum error 73h : Record head drive disabled (by EJECT lever) 82h : Power overvoltage detection 91h : Ambient temperature is higher that the allowable tempera- ture. - 15 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

MD-MS722/C/W/MS721W
– 15 –
•Whenever the DISP button is pressed in the continuous playback mode, the indication changes as follows.
* Pit section
Continuous playback (SUBQ address indication)
[
S
Q
]
|
Continuous playback (C1 error indication)
[
C
E
]
|
Continuous playback (SUBQ address indication)
[
S
Q
]
* Groove section
Continuous playback (ADIP address indication)
[
A
P
]
|
Continuous playback (C1 error indication)
[
C
E
]
|
Continuous playback (ADIP error indication)
[
A
E
]
|
Continuous playback (ADIP address indication)
[
A
P
]
8. TEST-REC Mode
• When the STOP button is pressed while the TEST-REC menu appears, or in the TEST-REC mode or continuous record mode, the mode
changes to the TEST mode stop state.
• When the PLAY button is pressed while the TEST-REC menu appears, the continuous record is initiated from the current pickup position.
• Whenever the DISP button is pressed in the TEST-REC mode, the address changes as follows.
0050 — 03C0 — 0700 — 08A0 — 0050 —
• Whenever the BASS button is pressed in the TEST-REC mode, the digit which is changed by the SKIP UP/DOWN button changes as
follows.
0050 — 0050 — 0050 — 0050 — 0050 —
• When the SKIP UP button s pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to +1h.(0 to F)
• When the SKIP DOWN button is pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to -1h. (0 to F)
* When the SKIP UP/DOWN button is held down, the setting changes continuously, one cycle being 100 ms.
• When the VOL UP/DOWN button is pressed in the TEST-REC mode or continuous record mode, the laser record power changes.
(Servo gain changes also according to record power.)
* After the laser record power is indicated for one second, the address indication is restored.
[
R
P
W
]
: Address
: Laser power cord
• Operation is disabled if the premastered disc or disc is in miserase-protected state.
9. NORMAL Mode
• When the STOP button is pressed while the NORMAl menu appears, the mode changes to the TEST mode stop state.
• Indication during operation
Indication of memory capacity on main unit LCD [
] + Level meter
: Internal mode
: Address (Cluster section)
: Address (Sector section)
• Selection of sound volume, BASS, etc. is possible (without indication)
• Recording is also possible.
10. Digital input display Mode (Din Mon)
• When the STOP button is pressed while the digital input indication menu appears or during digital input information indication, the mode
changes to the TEST mode stop state.
• In case of analog input or digital input unlocking the indication data is _.
11. Error data display Mode
• Reversing when SKIP DOWN button is pressed
• When the STOP button is pressed while the error data indication menu appears or during error data indication, the mode changes to the
TEST mode stop state.
• Error data 0 is the latest error.
• Error which occurred in the TEST mode is also stored in the memory.
• When the DISP button is pressed while the error data indication menu appears, the error data is initialized.
[
C
L
E
A
R _
]
: Error Code
Explanation of error history code
12h : RF side FG, TG, and TCRS adjustment termination failure
13h : Adjustment servo retraction excessive retrial
16h : C. IN detection time-over
17h : A, B, E, F, and TCRSO offset measurement value out of
tolerable range
21h : Focus retraction completion allowable time-over
23h : Track search completion allowable time-over
24h : Disc linear speed measurement failure
32h : P-TOC read failure
42h : U-TOC read failure
44h : U-TOC write data write disabled/read check error
52h : SD write data write disabled
71h : Pickup position initialization time-over
72h : EEPROM data read check sum error
73h : Record head drive disabled (by EJECT lever)
82h : Power overvoltage detection
91h : Ambient temperature is higher that the allowable tempera-
ture.