Tripp Lite 5PX1000RTNG2 Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2
Tripp Lite 5PX1000RTNG2 Manual
View all Tripp Lite 5PX1000RTNG2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Tripp Lite 5PX1000RTNG2 manual content summary:
- Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 1
Eaton 5PX Advanced User Guide 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 5PX1500RTNG2 5PX2000RTG2 5PX2000RTNG2 5PX2000RT3UNG2 5PX3000RTG2 5PX3000RTNG2 5PX3000RT3UNG2 5PXEBM48RTG2 5PXEBM72RTG2 5PXEBM72RT3UAG2 Copyright © 2021 EATON All rights reserved. 614-40095-00 - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 2
power source (the battery). Consequently, the power outlets may be energized even if the UPS is disconnected from the AC power source. Important instructions that must always be followed. CAUTION: Batteries present a risk of energy or electrical shock or burn from high short circuit current. Observe - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 3
Table of Contents 1 Introduction ...5 1.1 Environmental protection ...5 1.2 Benefits...6 2 Presentation...7 2.1 Standard installation ...7 2.2 Rear panel...8 2.3 Optional accessories...9 3 Installation ...9 3.1 Inspecting the equipment ...9 3.2 Recommended positions...11 3.3 Connecting the internal - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 4
the UPS equipped with a HotSwap MBP 34 6.6 Recycling the used equipment ...34 7 Troubleshooting...34 7.1 Typical alarms and faults...35 7.2 Silencing the alarm ...37 7.3 Service and support ...37 8 Specification and technical characteristics 37 8.1 UPS model list ...38 8.2 Extended Battery - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 5
information and safety instructions provided. Follow the instructions in the quick start guide and if necessary, refer to this advance user guide. To discover and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 6
End of life Eaton will process products at the end of their service life in compliance with local regulations. Eaton works with companies in charge of you least expect it and power quality can be erratic. These power problems have the potential to corrupt critical data, destroy unsaved work sessions, - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 7
2 Presentation 2.1 Standard installation Tower installation Rack installation Weights and dimensions Description (UPS) Weights (lb / kg) 5PX1000RTG2 5PX1000RTNG2 44.5 / 20.2 Dimentions (inch / mm) D x W x H 17.6x17.2x3.4 / 448x438x85.5 5PX1500RTG2 5PX1500RTNG2 50.7 / 23.0 17.6x17.2x3.4 / - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 8
2.2 Rear panel 5PX1000RTG2/5PX1000RTNG2 5PX1500RTG2/5PX1500RTNG2 5PX2000RTG2/5PX2000RTNG2 5PX3000RTG2/5PX3000RTNG2 5PX2000RT3UNG2 5PX3000RT3UNG2 5PXEBM48RTG2 - 5PXEBM72RTG2 5PXEBM72RT3UAG2 ① UPS ② Input AC power source ③ Primary group (critical equipment) ④ Outlet group (programmable outlets) ⑤ USB - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 9
damage: 1. File with the carrier within 15 days of receipt of the equipment; 2. Send a copy of the damage claim within 15 days to your service representative. Check the battery recharge date on the shipping carton label. If the date has passed and the batteries were never recharged, do not use - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 10
UPS ⑬ Connection cable to AC power source ⑮ RS232 communication cable ⑯ USB communication cable ⑰ Safety instructions ⑱ Quick start ⑳ Rack kit for 19-inch 4-post enclosures ㉑ Two supports for tower position (tower feet) ㉒ Communication card (optional) ㉓ FlexPDU module (optional) ㉕ HotSwap MBP module - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 11
3.2 Recommended positions Installation in tower position If you ordered other UPS accessories, refer to specific user manuals to check the tower installation with the UPS. To install the UPS: Place the UPS on a flat, stable surface in its final location. Always keep 6" - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 12
Installation in rack position Follow steps 1 to 4 for module mounting on the rails. The rails and necessary hardware are supplied by Eaton. 614-40095-00 12 - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 13
3.3 Connecting the internal battery A small amount of arcing may occur when connecting the internal batteries. This is normal and will not harm personnel. Connect the cables quickly and firmly. 1. Remove the front panel by pressing on both sides of the panel. 2. Connect the two battery connectors - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 14
Rack installation A small amount of arcing may occur when connecting an EBM to the UPS. This is normal and will not harm personnel. Insert the EBM cable into the UPS battery connector quickly and firmly. To increase stability, it is preferable to place the EBM below the UPS. 1. Fix the rail on the - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 15
differ, depending on the version of the FlexPDU module. 3.7 Connection with a HotSwap MBP (Maintenance ByPass) optional module The HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads (HotSwap function). 614-40095-00 15 - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 16
HotSwap MBP module operation 1. Connect the input socket (48) on the HotSwap MBP module to the AC power source. 2. Connect the UPS input power cord (13) to the receptacle "UPS Input" (47) of the HotSwap MBP module. 3. Connect the "UPS Output" cable (46) of the HotSwap MBP module to the outlet (3) - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 17
the warning level. The UPS has an active alarm or fault. See troubleshooting page for additional information. Led bar Static blue Flashing blue Static red Flashing the load is protected. The UPS is on battery or the battery service age warning is reached. The UPS has an active alarm or fault. - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 18
LCD automatically dims after 5 minutes of inactivity. Press any button to restore the screen. Note. If other indicator appears, see troubleshooting page for additional information. The following table describes the status information provided by the UPS : Operation status Possible cause Action - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 19
: V, f [Efficiency] : % [Battery Info] : %, min, V, number of EBM, Age service, Age Warning [Average power usage] : Toal, Primary, Group 1, Group 2 [Cumulative power] : Total View events View all Reset all View fault Reset faults Starts a manual battery test (possible if load >20% and battery >80%) - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 20
Main menu Submenu Identification Registration Display information or Menu function Type / Model / Part Number / Serial Number / UPS Firmware / NMC Firmware / IPV4 Address / IPV6 Address / Com card MAC Address Links to Eaton registration website 614-40095-00 20 - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 21
Español Português] [Italiano] [Simplified Chinese] [Japanese] Menus, status, notices and alarms, UPS fault, Event Log data and settings are in all supported languages. Default settings English Automatic message for user configuration when UPS is powered for the first time. Date / time Local LCD - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 22
Submenu Forced reboot Available settings [Yes] [No] [Timer] [10s] ... [180s] When mains recovers during a shutdown sequence: If set to Enabled, shutdown sequence will complete and wait 10 seconds prior to restart, If set to Disabled, shutdown sequence will not complete, UPS stays on. Default - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 23
to an extended power outage. Battery charge mode [ABM® cycling] [Constant charge] [ABM® cycling] External battery [Auto detection] [Manual EBM set.] [Manual battery set.] [Auto detection] Using standard EBM, UPS automatically detects the number of EBM connected Deep disch. protect. [Enabled - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 24
Submenu Available settings [DB9-7]: [On bat] [Low bat] [Bat fault] [UPS OK] [Load protected] [Load powered] [General alarm] [OVL prealarm] [DB9-8]: [On bat] [Low bat] [Bat fault] [UPS OK] [Load protected] [Load powered] [General alarm] [OVL prealarm] Default settings Remote command [Yes] [No] If - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 25
Connection of RS232/USB communication port 1. Connect the RS232 (15) or USB (16) communication cable to the serial or USB port on the computer equipment. 2. Connect the other end of the communication cable (15) or (16) to the USB (5) or RS232 (6) communication port on the UPS. The UPS can now - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 26
obtain humidity, temperature, smoke alarm, and security information. • Industrial Gateway card (INDGW-M2) : Provides Modbus RTU and Modbus TCP communication support in addition to the same secure UPS monitoring, management and sensor capability as the Gigabit Network card. • Relay-MS card : provides - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 27
Programmable signal inputs The 5PX incorporates several programmable signal inputs: one Remote Power Off (RPO) input terminal, one Remote On/ Off (ROO) input terminal, one RS-232 input (pin-4). Signal inputs can be configured (see Settings > Comm settings > Signal Input) to have one of the following - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 28
• On/Off control via button has priority over the remote control. The ROO function is only active after the first use of the "Remote OFF" function. ROO Connector type Terminal rating Comments Terminal, 14 AWG Maximum wires 60 V DC/30 V AC 20 mA max Remote control connection and test 1. Check the - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 29
active alarms or notices. Resolve any active alarms before continuing; if the indicator is on, do not proceed until all alarms are clear (see "Troubleshooting" section). Check the UPS status from the front panel to view the active alarms. Correct the alarms and restart if necessary. 6. Verify that - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 30
alarms or notices besides the "Battery mode" and related notifications that indicates missing utility power. Resolve any active alarms before continuing. See "Troubleshooting". Check the UPS status from the front panel to view the active alarms. Correct the alarms and restart if necessary. 5.3 UPS - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 31
cleaner. For full battery life, keep the equipment at an ambient temperature of 25 °C (77 °F). The batteries are rated for a 3-5 year service life. The length of service life varies, depending on the frequency of usage and ambient temperature (life divided by 2 each 10 °C above 25 °C). If the UPS - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 32
UPS is in Battery mode. For battery replacement, follow Eaton instructions provided on www.eaton.com/UPSservices . Batteries can be replaced the same type and number of batteries or battery packs. Contact your service representative to order new batteries. • Proper disposal of batteries is required - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 33
Replacing the internal battery : The internal battery is heavy. Use caution when handling the heavy batteries. A Phillips head screwdriver is needed to perform this procedure 1 - Pull off the front panel by pressing the tabs on both sides. 2 - Disconnect the battery pack by separating the connectors - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 34
UPS equipped with a HotSwap MBP The HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads (HotSwap function). your local recycling/reuse or hazardous waste center. 7 Troubleshooting The Eaton 5PX is designed for reliable, autonomous operation - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 35
and red LED, recorded into the Fault log and displayed on the LCD with a specific message box. Example = Out. short circuit. Use the following troubleshooting chart to determine the UPS alarm condition. 7.1 Typical alarms and faults To check the Event log or Fault log: 1. Press any button on the - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 36
. Allow the UPS to cool. Ensure the airflow around the UPS is not restricted. Restart the UPS. If the condition continues to persist, contact your service representative. The UPS does not start The input source is not connected correctly. Check the input and battery connections. 614-40095-00 36 - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 37
. If the alarm status changes, the alarm beeps again, overriding the previous alarm silencing. 7.3 Service and support If you have any question or problem with the UPS, call Eaton or your local service representative in your country / region. Please have the following information ready when you call - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 38
8.1 UPS model list Description Eaton 5PX 1000 RT2U G2 Eaton 5PX 1000 RT2U Netpack G2 Catalog Number 5PX1000RTG2 5PX1000RTNG2 Power rating 1000W/1000VA Configuration Rack / Tower Eaton 5PX 1500 RT2U G2 Eaton 5PX 1500 RT2U Netpack G2 5PX1500RTG2 5PX1500RTNG2 1440W/1440VA Rack / Tower Eaton 5PX - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 39
Description (EBM) 5PXEBM48RTG2 5PXEBM72RTG2 5PXEBM72RT3UAG2 Weights (lb / kg) 61.3 / 27.8 89.1 / 40.4 87.5 / 39.7 Dimentions (inch / mm) D x W x H 17.6x17.2x3.4 / 448x438x85.5 23.7x17.2x3.4 / 603x438x85.5 19x17.2x5.1 / 483x438x129 8.3 Electrical input Default frequency 60Hz Nominal frequency 50 - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 40
8.5 Electrical output All models Voltage regulation Efficiency Frequency regulation Nominal output Frequency Output overload Short circuit current limitation in battery mode Transfer time Normal mode Boost : Vin*1.15 Buck : Vin*0.87 >96% 100/110/120/125V Battery mode (-10% ,6%) 1000-2200 > 82% - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 41
: 72Vdc - 2 x 6 x 12V, 9Ah 5PXEBM72RT3UAG2: 72Vdc - 2 x 6 x 12V, 9Ah Type Sealed, maintenance-free, valve-regulated, lead-acid, with minimum 3-5 year float service life at 25°C (77°F). Monitoring EBM battery cable length Advanced monitoring for earlier failure detection and warning 2U EBM cable - Tripp Lite 5PX1000RTNG2 | Owners Manual for 5PX1000RTG2 5PX1000RTNG2 5PX1500RTG2 - Page 42
Storage temperature Relative humidity Operating altitude Transit altitude Audible noise 9 Glossary AVR Backup time EBM Low-battery warning Load Normal mode Normal AC source OVL Relay contacts UPS -15 to 50°C (5 to 122 °F) 20 to 90 % (without condensation) Up to 3,000 meters (9,843 ft) above sea
Eaton 5PX
Advanced User Guide
Copyright © 2021 EATON
All rights reserved.
614-40095-00
5PX1000RTG2
5PX1000RTNG2
5PX1500RTG2
5PX1500RTNG2
5PX2000RTG2
5PX2000RTNG2
5PX2000RT3UNG2
5PX3000RTG2
5PX3000RTNG2
5PX3000RT3UNG2
5PXEBM48RTG2
5PXEBM72RTG2
5PXEBM72RT3UAG2