Tripp Lite 9PX11KTF11M Eaton 9PX UPS 700-3000 VA 2U Owners Manual - Page 39
Troubleshooting
View all Tripp Lite 9PX11KTF11M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
ENGLISH 7. Troubleshooting The Eaton 9PX are designed for durable, automatic operation and also alert you whenever potential operating problems may occur. Usually the alarms shown by the control panel do not mean that the output power is affected. Instead, they are preventive alarms intended to alert the user. • Events are silent status information that are recorded into the Event log. Example = "AC freq in range". • Alarms are recorded into the Event log and displayed on the LCD status screen with the logo blinking. Some alarms may be announced by a beep every 3 seconds. Example = "Battery low". • Faults are announced by a continuous beep and red LED, recorded into the Fault log and displayed on the LCD with a specific message box. Example = Out. short circuit. Use the following troubleshooting chart to determine the UPS alarm condition. 7.1 Typical alarms and faults To check the Event log or Fault log : 1. Press any button on the front panel display to activate the menu options. 2. Press the button to select Event log or Fault log. 3. Scroll through the listed events or faults. The following table describes typical conditions. Conditions Battery mode Possible cause A utility failure has occurred and the UPS is in Battery mode. LED is On. 1 beep every 10 seconds. Battery low The UPS is in Battery mode and the battery is running low. LED is On. 1 beep every 3 seconds. Action The UPS is powering the equipment with battery power. Prepare your equipment for shutdown. This warning is approximate, and the actual time to shutdown may vary significantly. Depending on the UPS load and number of Extended Battery Modules (EBMs), the "Battery Low" warning may occur before the batteries reach 20% capacity. No battery LED is On. Beep continuous. Battery fault LED is On. Beep continuous. The UPS does not provide the expected backup time. Bypass mode LED is on. The batteries are disconnected. Verify that all batteries are properly connected. If the condition persists, contact your service representative. The battery test is failed due to bad or disconnected batteries, or the battery minimum voltage is reached in ABM cycling mode. Verify that all batteries are properly connected. Start a new battery test: if the condition persists, contact your service representative. The batteries need charging or service. An overload or a fault has occurred, or a command has been received and the UPS is in Bypass mode Apply utility power for 48 hours to charge the batteries. If the condition persists, contact your service representative. Equipment is powered but not protected by the UPS. Check for one of the following alarms: overtemperature, overload or UPS failure. Power overload LED is On. Beep continuous. Power requirements exceed the UPS capacity (greater than 100% of nominal; see in table 6 on page 42 for specific output overload ranges). Remove some of the equipment from the UPS. The UPS continues to operate, but may switch to Bypass mode or shut down if the load increases. The alarm resets when the condition becomes inactive. 9PX 1-3 KVA US_EN Page 39