Tripp Lite SU5000RT4U Owner's Manual for SU5000RT4U/SU6000RT4U/SU8000RT4U UPS - Page 15

Shutdown Messages

Page 15 highlights

Operation (continued) Shutdown Messages Your UPS will shut down and the LCD will display a message if it detects one of the following conditions. Note: During all these conditions, the "Input," "Output" and "Bypass" LEDs will be illuminated. Shutdown Conditions LCD Screen Messages Shutdown Conditions LCD Screen Messages L1 Extended Overload SHUTDOWN L1 OVERLOAD=XXX% Internal Charger Failure INT CHARGER FAIL LOAD1 = XXX% X.XKW L2 Extended Overload L1 to L2 Output Short Circuit SHUTDOWN L2 OVERLOAD=XXX% OP SHORTCIRCUIT LOAD1 = XXX% X.XKW External Charger Failure Battery Open / Bad Battery EXT CHARGER FAIL LOAD1 = XXX% X.XKW BAD BATTERY! LOAD1 = XXX% X.XKW L1 to N Output Short Circuit L2 to N Output Short Circuit OP1 SHORTCIRCUIT LOAD1 = XXX% X.XKW OP2 SHORTCIRCUIT LOAD1 = XXX% X.XKW Phase Lock Failure, Bypass Lockout Phase Lock Failure, Inverter Lockout BYPASS LOCKOUT LOAD1 = XXX% X.XKW INVERTER LOCKOUT LOAD1 = XXX% X.XKW Remote Shutdown Command (via DB9) REMOTE COMMAND LOAD1 = XXX% X.XKW Remote Shutdown Command (via EPO) EMERGENCY STOP! LOAD1 = XXX% X.XKW Battery Depletion LOW BATTERY LOAD1 = XXX% X.XKW Site Wiring Fault SITE WIRING FAULT LOAD1 = XXX% X.XKW EEPROM Failure EEPROM FAIL LOAD1 = XXX% X.XKW Positive DC BUS Voltage is Too High +DC BUS HIGH LOAD1 = XXX% X.XKW Positive DC BUS Voltage is Too Low Negative DC BUS Voltage is Too High +DC BUS LOW LOAD1 = XXX% X.XKW -DC BUS HIGH LOAD1 = XXX% X.XKW Negative DC BUS Voltage is Too Low -DC BUS LOW LOAD1 = XXX% X.XKW Fan Failure FAN FAIL LOAD1 = XXX% X.XKW UPS Overtemperature OVERTEMPERATURE LOAD1 = XXX% X.XKW L1 Inverter Too High INVERTER1 HIGH LOAD1 = XXX% X.XKW L1 Inverter Too Low INVERTER1 LOW LOAD1 = XXX% X.XKW L2 Inverter Too High INVERTER2 HIGH LOAD1 = XXX% X.XKW L2 Inverter Too Low INVERTER2 LOW LOAD1 = XXX% X.XKW 15 201102170 932611.indd 15 3/30/2011 10:22:18 AM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

15
Operation
(continued)
Shutdown Messages
Your UPS will shut down and the LCD will display a message if it detects one of the following conditions. Note: During all these conditions,
the “Input,” “Output” and “Bypass” LEDs will be illuminated.
Shutdown Conditions
L1 Extended Overload
L2 Extended Overload
L1 to L2
Output Short Circuit
L1 to N Output Short Circuit
L2 to N Output Short Circuit
Remote Shutdown Command
(via DB9)
Remote Shutdown Command
(via EPO)
Battery Depletion
Site Wiring Fault
EEPROM Failure
Positive DC BUS Voltage
is Too High
Positive DC BUS Voltage
is Too Low
Negative DC BUS Voltage
is Too High
Negative DC BUS Voltage
is Too Low
Fan Failure
UPS Overtemperature
L1 Inverter Too High
L1 Inverter Too Low
SHUTDOWN
L1 OVERLOAD=XXX%
LCD Screen Messages
SHUTDOWN
L2 OVERLOAD=XXX%
OP SHORTCIRCUIT
LOAD1 = XXX% X.XKW
OP1 SHORTCIRCUIT
LOAD1 = XXX% X.XKW
OP2 SHORTCIRCUIT
LOAD1 = XXX% X.XKW
REMOTE COMMAND
LOAD1 = XXX% X.XKW
EMERGENCY STOP!
LOAD1 = XXX% X.XKW
SITE WIRING FAULT
LOAD1 = XXX% X.XKW
EEPROM FAIL
LOAD1 = XXX% X.XKW
+DC BUS HIGH
LOAD1 = XXX% X.XKW
+DC BUS LOW
LOAD1 = XXX% X.XKW
-DC BUS HIGH
LOAD1 = XXX% X.XKW
-DC BUS LOW
LOAD1 = XXX% X.XKW
FAN FAIL
LOAD1 = XXX% X.XKW
OVERTEMPERATURE
LOAD1 = XXX% X.XKW
LOW BATTERY
LOAD1 = XXX% X.XKW
INVERTER1 HIGH
LOAD1 = XXX% X.XKW
INVERTER1 LOW
LOAD1 = XXX% X.XKW
L2 Inverter Too High
L2 Inverter Too Low
INVERTER2 HIGH
LOAD1 = XXX% X.XKW
INVERTER2 LOW
LOAD1 = XXX% X.XKW
Shutdown Conditions
Internal Charger Failure
External Charger Failure
Battery Open / Bad Battery
Phase Lock Failure,
Bypass Lockout
Phase Lock Failure,
Inverter Lockout
INT CHARGER FAIL
LOAD1 = XXX% X.XKW
LCD Screen Messages
EXT CHARGER FAIL
LOAD1 = XXX% X.XKW
BAD BATTERY!
LOAD1 = XXX% X.XKW
BYPASS LOCKOUT
LOAD1 = XXX% X.XKW
INVERTER LOCKOUT
LOAD1 = XXX% X.XKW
201102170
932611.indd
15
3/30/2011
10:22:18 AM