    Installation Professional Indoor & Outdoor Hoods VWH53012 / VWH53612 VWH53048 / VWH53648 / VWH54248 VWH54848 / VWH56048 VCWH53048 / VCWH53648 / VCWH54248 VCWH54848 / VCWH56048 VCIH53608 / VCIH54208 / VCIH55408 / VCIH56608 VBCV53638 / VBCV54238 / VBCV54838 / VBCV56038 / VBCV56038 VWHO3678 / VWHO4878
  • Viking VWH | Installation Instructions - Page 2
    Hoods 33 Duct Cover Option (VWH/CVWH 18"H. Wall Hoods 34 Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods 35 Installation (VCIH Island Hoods 36 Service & Registration 38 Wiring Diagram 39 2
  • Viking VWH | Installation Instructions - Page 3
    elements as much as possible. • The installer should leave these instructions with the consumer who should retain for local inspector's use and the electricity to the hood from the power supply before servicing or cleaning. Viking hoods are equipped with variable speed control blowers. These units
  • Viking VWH | Installation Instructions - Page 4
    children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not
  • Viking VWH | Installation Instructions - Page 5
    Dimensions & Specifications (VWH 10"H./12"H. Wall Hoods w/Standard Ventilator 30", & 36") (12.57"cm) (301.25 " cm) (251.40"cm) A (532.31"cm) A (Hood width) 30"W. 29-7/8" (76.2 cm) 36"W. 35-7/8" (91.1 cm) (12.57"cm) A (532.31"cm) NOTE: Optional duct cover sold separately. A (Hood width)
  • Viking VWH | Installation Instructions - Page 6
    Clearance Dimensions (VWH/CVWH 10"H./12"H. Wall Hoods w/Standard Ventilator) (913.46"cm) 6((6113056"20"t..mo40mccaimmnx.)). 22((7664"18"..tm06omccammixn))..* * NOTE: When installing with a 24" high-shelf, the 27" (68.6 cm) max. dimensions must be used. 6
  • Viking VWH | Installation Instructions - Page 7
    Interior Ventilator Dimensions (VWH/CVWH 10"H./12"H. Wall Hoods w/Standard Ventilator) Top View 24"W. 30"W. 36"W. 24"W. 30"W. 36"W. 24"W. 30"W. 36"W. 24"W. 30"W. 36"W. A 23-7/8" (60.6 cm) 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) B 5-1/4" (13.3 cm) 8-1/4" (20.9 cm) 11-1/4" (28.6 cm) C 11-15/16" (30.3
  • Viking VWH | Installation Instructions - Page 8
    Dimensions & Specifications (VWH/CVWH 18"H. 24" Deep Wall Hoods 30", 36", 42", 48", & 60") 30" W 36" W 42" W 48" W 60" W A 29-7/8" (76.2 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 59-7/8" (152.1 cm) (15.62"cm) (301.52"cm) (451.78"cm) A (612.04"cm) NOTE: Optional duct cover
  • Viking VWH | Installation Instructions - Page 9
    Clearance Dimensions (VWH/CVWH 18"H. Wall Hoods) (913.46"cm) 7((6112668"72"t..mo69mccaimmnx.)). 33((796061""..t24momccamminx)).. 9
  • Viking VWH | Installation Instructions - Page 10
    Interior Ventilator Dimensions (VWH/CVWH 18"H. Wall Hoods) 30" W 36" W 42" W 48" W 60" W A 14-15/16" (37.9 cm) 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) 23-15/16" (60.8 cm) 29-15/16" (76.0 cm) Top View A 4-5/8" (11.7 cm) 7" (17.8 cm) dia. duct location 30" W 36" W 42" W 48" W 60" W B 29-7/8" (75
  • Viking VWH | Installation Instructions - Page 11
    Exterior Ventilator Dimensions (VWH/CVWH 18"H. Wall Hoods) 30" W 36" W 42" W 48" W 60" W A 14-15/16" (37.9 cm) 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) 23-15/16" (60.8 cm) 29-15/16" (76.0 cm) Top View A 5-15/16" (15.1 cm) 10" (25.4 cm) dia. duct location 30" W 36" W 42" W 48" W 60" W B 29-7/8" (
  • Viking VWH | Installation Instructions - Page 12
    Dimensions & Specifications (VWHO/CVWHO 18"H. Outdoor Wall Hoods 36", 48", & 60") (15.62"cm) A 36" W 35-7/8" (91.1 cm) A 48" W 47-7/8" (121.6 cm) 60" W 59-7/8" (152.1 cm) (682.67c"m) (451.78c"m) VWHO/CVWHO 18"H. Outdoor Wall Hoods Description Number of lights Number of filters Interior
  • Viking VWH | Installation Instructions - Page 13
    Clearance Dimensions (VWHO/CVWHO 18"H. Outdoor Wall Hoods) (45.7 1cm8") ((76112686"72"t..mmo69 ccainmmx..)) (913.46c"m) D(+1I1M4.-41«c/Xm2")» (682.67c"m) 3(3(796061""..t42mmoccaimmnx).). Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from the
  • Viking VWH | Installation Instructions - Page 14
    Dimensions & Specifications (VCWH/CVCWH Chimney Wall Hoods 30", 36", 42", 48", 54", & 60") A A (Duct width) 30"W. 12" (30.5 cm) 36"W. 12" (30.5 cm) 42"W. 12" (30.5 cm) 48"W. 18" (45.7 cm) 60"W. 24" (61.0 cm) 66"W. 24" (61.0 cm) B (Hood width) 30"W. 29-7/8" (76.2 cm) (15.62"cm) 36"W. 35-7/8" (91
  • Viking VWH | Installation Instructions - Page 15
    Clearance Dimensions (VCWH/CVCWH Chimney Wall Hoods) (913.46"cm) 7((6112668"72"t..mo69mccaimmnx.)). 33((796061""..t24momccamminx)).. 15
  • Viking VWH | Installation Instructions - Page 16
    Interior Ventilator Dimensions (VCWH/CVCWH Chimney Wall Hoods) 30"W. 36"W. 42"W. 30"W. 36"W. 42"W. A 14-15/16" (37.9 cm) 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) B 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) Top View 12" (30.5 cm) 1-1/2" (3.8 cm) 120V power supply A 6" (15.2 cm)
  • Viking VWH | Installation Instructions - Page 17
    Exterior Ventilator Dimensions (VCWH/CVCWH Chimney Wall Hoods) 30"W. 36"W. 42"W. 30"W. 36"W. 42"W. Top View 12" (30.5 cm) 1-1/2" (3.8 cm) A 120V power supply A 14-15/16" (37.9 cm) 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) B 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 6" (15.2 cm)
  • Viking VWH | Installation Instructions - Page 18
    Dimensions & Specifications (VCIH/CVCIH Chimney Island Hoods 36", 42", 54", & 66") A 36" W 42" W 54" W 66" W 36" W. 42" W. 54" W. 66" W. A 12" (30.5 cm) 12" (30.5 cm) 18" (45.7 cm) 24" (70.0 cm) B 12" (30.5 cm) or 24" (61.0 cm) or 36" (91.4 cm) (15.62"cm) 36" W 42" W 54" W 66" W C 35-7/8" (91
  • Viking VWH | Installation Instructions - Page 19
    Clearance Dimensions (VCIH /CVCIHChimney Island Hoods) (913.46"cm) 7((6112668"72"t..mo69mccaimmnx.)). 3((3796061""..t24mmoccaimmnx)).. 19
  • Viking VWH | Installation Instructions - Page 20
    Interior Ventilator Dimensions (VCIH/CVCIH Chimney Island Hoods) Top View 12" (30.5 cm) 36"W. 42"W. 36"W. 42"W. A 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) B 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) A 6" (15.2 cm) 1-1/8" (2.9 cm) 120 V power supply 1-1/8" (2.9 cm) 7" (17.8 cm) dia. duct location B
  • Viking VWH | Installation Instructions - Page 21
    Exterior Ventilator Dimensions (VCIH/CVCIH Chimney Island Hoods) Top View 12" (30.5 cm) 36"W. 42"W. 36"W. 42"W. A 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) B 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) A 6" (15.2 cm) 1-1/8" (2.9 cm) 120 V power supply 1-1/8" (2.9 cm) 10" (25.4 cm) dia. duct location B
  • Viking VWH | Installation Instructions - Page 22
    Dimensions & Specifications (VBCV Wall Custom Ventilator System 36", 42", 48", & 60") A* *For best results, center the unit over B* the burners of the cooking product (front to back; right to left). Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator
  • Viking VWH | Installation Instructions - Page 23
    Installing Hood Canopy (Custom Hood Canopy Cutouts) Custom Hood Canopy A B 1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right. 2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided. Built
  • Viking VWH | Installation Instructions - Page 24
    Clearance Dimensions (VBCV/CVBCV Wall Custom Ventilator System) (Custom Hood) (913.46"cm) 7((6112668"72"t..mo69mccaimmnx.)). 33((796061""..t24momccamminx)).. 24
  • Viking VWH | Installation Instructions - Page 25
    Built-In Wall Custom Ventilator System Dimensions (VBCV Models) 1-1/2" (3.81 cm) 1" (2.54 cm) 17-1/4" (43.8 cm) 5/8" (1.6 cm) 21-7/8" (55.8 cm) For 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation 6" (15.2 cm) 1-1/2" (3.8 cm) 7/8" (2.2 cm) 11-1/2" (29.2 cm) 17-1/4" (43.8
  • Viking VWH | Installation Instructions - Page 26
    Built-In Wall Custom Ventilator System Dimensions (VBCV/CVBCV Models) D 5-1/2" (14.0 cm) 10" (25.4 cm) dia. duct location 5/8" (1.6 cm) C 1200 or 1500 CFM Exterior or In-Line Ventilator Installation 48", 60" W. Models D 5-1/2" (14.0 cm) 10" (25.4 cm) dia. duct location 5/8" (1.6 cm) C 1200 CFM
  • Viking VWH | Installation Instructions - Page 27
    Planning Information Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product. • All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated. • Straight runs and gradual turns are best;
  • Viking VWH | Installation Instructions - Page 28
    . If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device
  • Viking VWH | Installation Instructions - Page 29
    6 Nut driver 5/16" CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary. 7 Bare or Green White White Green Black Black 5/16" Nut driver CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws
  • Viking VWH | Installation Instructions - Page 30
    Duct Cover Option (VWH/CVWH 10"H./12"H. Wall Hoods w/Standard Ventilator) 1 2 2 Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. Installation (VWH/CVWH 10"H./12"H. Wall Hoods w/Recirculating Kit) 1 2
  • Viking VWH | Installation Instructions - Page 31
    . If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device
  • Viking VWH | Installation Instructions - Page 32
    Installation (con't) (VWH/CVWH 10"H./12"H. Wall Hoods w/Recirculating Kit) 8 Bare or Green White White Green Black Black 9 1 1 2 Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring to be correct when
  • Viking VWH | Installation Instructions - Page 33
    Installation (VWH/CVWH 18"H. Wall & VCWH Chimney Wall Hoods) *For VCWH hoods, begin with Step 3. The VCWH hoods do not require the wood strip 1 1-1/2" x 3/4" (3.8 cm) x ( 1.9 cm) wood strip 1(4-.163c/1m6)" 2 5/16" Nut driver 5/16" Nut driver VWH/CVWH only! Measure down 1-13/16 (4.6 cm) from
  • Viking VWH | Installation Instructions - Page 34
    Duct Cover Option (VWH/CVWH 18"H. Wall Hoods) 1 2 2 Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. To install ventillation kit refer to ventillation kit installation instructions. 34
  • Viking VWH | Installation Instructions - Page 35
    Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) 1 2 Measure distance from ceiling to canopy. 3 Tape to avoid scratching. 4 2 Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place and remove tape.
  • Viking VWH | Installation Instructions - Page 36
    be. NOTE: 200 lb. limit. Mounting options: Using duct cover with ceiling mounting bracket. (Option A - VCIH only) Using threaded rod for additional support. (Option B) Attaching hood directly to soffit or duct cover. (Skip to step 3) Cut appropriate size hole in ceiling. Either 7" or 10" depending
  • Viking VWH | Installation Instructions - Page 37
    hood to duct with aluminum tape. To install ventillation kit refer to ventillation kit installation instructions. •Install larger center spacer in middle of canopy •Slide grease trough down into filter support with lip facing upward •Attach long edge of side spacers to outer side of baffle filters
  • Viking VWH | Installation Instructions - Page 38
    service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-4641), or write to: VIKING RANGE, LLC PREFERRED SERVICE If service requires installation of parts, use only authorized parts to ensure protection under the warranty. THIS MANUAL SHOULD REMAIN
  • Viking VWH | Installation Instructions - Page 39
    39
  • Viking VWH | Installation Instructions - Page 40
    Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com F21287i EN (050120)
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Installation
Professional Indoor & Outdoor Hoods
VWH53012 /
VWH53612
VWH53048 / VWH53648 / VWH54248
VWH54848 / VWH56048
VCWH53048 / VCWH53648 / VCWH54248
VCWH54848 / VCWH56048
VCIH53608 / VCIH54208 / VCIH55408 / VCIH56608
VBCV53638 / VBCV54238 / VBCV54838 / VBCV56038 / VBCV56038
VWHO3678 / VWHO4878 / VWHO6078 (Canadian Outdoor models not applicable)