Viking VWH Installation Instructions - Page 18

VCIH/CVCIH Chimney Island Hoods

Page 18 highlights

Dimensions & Specifications (VCIH/CVCIH Chimney Island Hoods 36", 42", 54", & 66") A 36" W 42" W 54" W 66" W 36" W. 42" W. 54" W. 66" W. A 12" (30.5 cm) 12" (30.5 cm) 18" (45.7 cm) 24" (70.0 cm) B 12" (30.5 cm) or 24" (61.0 cm) or 36" (91.4 cm) (15.62"cm) 36" W 42" W 54" W 66" W C 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 53-7/8" (136.8 cm) 65-7/8" (167.3 cm) C (763.20"cm) NOTE: Optional duct cover sold separately. VCIH/CVCIH Chimney Island Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 36" 12" (30.5 cm) 4 4 VINV600 DEV900/1200* DIL1200 7" (17.8 cm) 42" 54" 12" (30.5 cm) 18" (45.7 cm) 12" (30.5 cm) 12" (30.5 cm) or 24" (61.0 cm) or 36" (91.4 cm) 4 6 4 6 VINV600 N/A VINV1200* DEV900/1200*/1500** DEV1200*/1500** DIL1200 DIL1200 7" (17.8 cm) 10" (25.4 cm) Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-Line-Maximum amps 4.2/5.2/8.2 7.4/4.7 4.7/6.5 10" (25.4 cm) 5.2/8.2 7.4/4.7/5.5 3.9/5.7 8.9 5.6/6.4 7.4 B (451.78"cm) 66" 24" (70.0 cm) 8 8 VINV1200* DEV1200*/1500** DIL1200 10" (25.4 cm) 9.3 6.4/7.4 7.4 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

18
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is
50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An
interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
30"
(76.2 cm)
C
A
18"
(45.7 cm)
B
6"
(15.2 cm)
C
36" W
35-7/8" (91.1 cm)
42" W
41-7/8" (106.4 cm)
54" W
53-7/8" (136.8 cm)
66" W
65-7/8" (167.3 cm)
B
36" W.
42" W.
54" W.
66" W.
12" (30.5 cm)
or
24" (61.0 cm)
or
36" (91.4 cm)
A
36" W
12" (30.5 cm)
42" W
12" (30.5 cm)
54" W
18" (45.7 cm)
66" W
24" (70.0 cm)
NOTE: Optional duct cover sold separately.
(VCIH/CVCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)
VCIH/CVCIH Chimney Island Hoods
Description
36”
42”
54”
66”
Duct cover width
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
24” (70.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)
Number of lights
4
4
6
8
Number of filters
4
4
6
8
Heat lamps
N/A
Interior ventilator kits
VINV600
VINV600
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/1200*
DEV900/1200*/1500**
DEV1200*/1500**
DEV1200*/1500**
In-line ventilator kits
DIL1200
DIL1200
DIL1200
DIL1200
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.2/5.2/8.2
5.2/8.2
8.9
9.3
Exterior—Maximum amps
7.4/4.7
7.4/4.7/5.5
5.6/6.4
6.4/7.4
In-Line—Maximum amps
4.7/6.5
3.9/5.7
7.4
7.4