Dimensions & Specifications (VWH/CVWH 18"H. 24" Deep Wall Hoods 30", 36", 42", 48", & 60") 30" W 36" W 42" W 48" W 60" W A 29-7/8" (76.2 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 59-7/8" (152.1 cm) (15.62"cm) (301.52"cm) (451.78"cm) A (612.04"cm) NOTE: Optional duct cover sold separately. VWH/CVWH 18"H. Wall Hoods Description 30" 36" 42" 48" Duct cover width 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) Duct cover depth Duct cover height Number of lights 12" (30.5 cm) 12" (30.5 cm) 2 2 2 3 Number of filters 2 2 2 3 Heat lamps 1 1 1 2 Interior ventilator kits Exterior ventilator kits In-line ventilator kits VINV300/ 600/1200 DEV900/ 1200* DIL1200 VINV300/ 600/1200 DEV900/ 1200* DIL1200 VINV600/ 1200 DEV900/ 1200* DIL1200 VINV1200* DEV1200*/ 1500** DIL1200 Interior duct size 7"/10" 7"/10" 7"/10" (17.8/25.4 cm) (17.8/25.4 cm) (17.8/25.4 cm) 10" (25.4 cm) Exterior duct size 10" (24.5 cm) Interior-Maximum amps Exterior-Maximum amps 4.2/5.2/8.2 8.0/5.3 4.2/5.2/8.2 8.0/5.3 5.2/8.2 8.0/5.3 10.8 7.8/8.5 In-Line-Maximum amps 5.3/7.2 5.3/7.2 5.3/7.2 9.6 60" 59-7/8" (152.1 cm) 4 4 3 VINV1200* DEV1200*/ 1500** DIL1200 10" (25.4 cm) 10.8 7.8/8.5 10.0 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

8
24"
(61.0 cm)
A
18"
(45.7 cm)
12"
(30.5 cm)
6"
(15.2 cm)
A
30" W
29-7/8" (76.2 cm)
36" W
35-7/8" (91.1 cm)
42" W
41-7/8" (106.4 cm)
48" W
47-7/8" (121.6 cm)
60" W
59-7/8" (152.1 cm)
(VWH/CVWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max
duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with
ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
NOTE: Optional duct cover sold separately.
VWH/CVWH 18”H. Wall Hoods
Description
30”
36”
42”
48”
60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
59-7/8”
(152.1
cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2
2
2
3
4
Number of filters
2
2
2
3
4
Heat lamps
1
1
1
2
3
Interior ventilator kits
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200
DIL1200
DIL1200
DIL1200
DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (24.5 cm)
Interior—Maximum amps
4.2/5.2/8.2
4.2/5.2/8.2
5.2/8.2
10.8
10.8
Exterior—Maximum amps
8.0/5.3
8.0/5.3
8.0/5.3
7.8/8.5
7.8/8.5
In-Line—Maximum amps
5.3/7.2
5.3/7.2
5.3/7.2
9.6
10.0