Weslo Cardioglide 950 English Manual - Page 7

Maintenance, Trouble, Shooting

Page 7 highlights

• MAINTENANCE AND TROUBLE-SHOOTING MONITOR CARE Keep the monitor out of direct sunlight or the LCD display may be damaged. The monitor can be cleaned using a soft, dry cloth. Do not allow liquid to come in contact with the monitor. Remove the batteries when storing the CARDIOGLIDE 950. REPLACING THE BATTERIES If the display of the Monitor (1) becomes dim, the two L1154 watch batteries should be replaced. Remove the #8 x 1/2" Screw (16) from the back of the Monitor. Remove the two screws from the back cover of the Monitor and remove the back cover. Push the two old batteries out of the clips, and insert two new batteries. 6 Reattach the back cover and reattach the Monitor (1) to the Frame (6). Make sure that the wire on the Monitor is plugged into the sensor wire. Insert any excess wire into the Frame. Make sure not to pinch the wire between the Frame and the Monitor. Screws Batteries 16 4e 5 ADJUSTING THE MAGNET AND REED SWITCH If the monitor does not function properly, the Magnet (27) and Reed Switch (15) should be checked. Pivot the Pedal Frame (7) until the Magnet is aligned with the Reed Switch. Loosen the #8 x 3/4" Screw (35) and adjust the position of the Reed Switch so that there is a 1/8" gap between the Magnet and the Reed Switch. Retighten the #8 x 3/4" Screw. 7 27 15 15 35 27 LUBRICATING THE CARDIOGLIDE 950 The ends of the Link Arms (4) should be oiled every six months. Apply a few drops of light multi-purpose oil (not included) between the Link Arms and the dome caps in the indicated locations. Apply Oil 4 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

MAINTENANCE
AND
TROUBLE
-SHOOTING
MONITOR
CARE
Keep
the
monitor
out
of
direct
sunlight
or
the
LCD
display
may
be
damaged.
The
monitor
can
be
cleaned
using
a
soft,
dry
cloth.
Do
not
allow
liquid
to
come
in
contact
with
the
monitor.
Remove
the
batteries
when
storing
the
CARDIOGLIDE
950.
REPLACING
THE
BATTERIES
If
the
display
of
the
Monitor
(1)
becomes
dim,
the
two
L1154
watch
batteries
should
be
replaced.
Remove
the
#8
x
1/2"
Screw
(16)
from
the
back
of
the
Monitor.
Remove
the
two
screws
from
the
back
cover
of
the
Monitor
and
remove
the
back
cover.
Push
the
two
old
batteries
out
of
the
clips,
and
insert
two
new
batteries.
6
Reattach
the
back
cover
and
reattach
the
Monitor
(1)
to
the
Frame
(6).
Make
sure
that
the
wire
on
the
Monitor
is
plugged
into
the
sensor
wire.
Insert
any
excess
wire
into
the
Frame.
Make
sure
not
to
pinch
the
wire
between
the
Frame
and
the
Monitor.
ADJUSTING
THE
MAGNET
AND
REED
SWITCH
If
the
monitor
does
not
function
properly,
the
Magnet
(27)
and
Reed
Switch
(15)
should
be
checked.
Pivot
the
Pedal
Frame
(7)
until
the
Magnet
is
aligned
with
the
Reed
Switch.
Loosen
the
#8
x
3/4"
Screw
(35)
and
adjust
the
position
of
the
Reed
Switch
so
that
there
is
a
1/8"
gap
between
the
Magnet
and
the
Reed
Switch.
Retighten
the
#8
x
3/4"
Screw.
LUBRICATING
THE
CARDIOGLIDE
950
The
ends
of
the
Link
Arms
(4)
should
be
oiled
every
six
months.
Apply
a
few
drops
of
light
multi
-purpose
oil
(not
included)
between
the
Link
Arms
and
the
dome
caps
in
the
indicated
locations.
8
16
Screws
4e
Batteries
5
27
15
7
27
15
35
Apply
Oil
4