Whirlpool WED94HEXW Installation Instructions - Page 14

Plan Vent System

Page 14 highlights

Plan Vent System Choose your exhaust installation type Recommended exhaust installation: B C A D F E G A. Dryer B Elbow C. Wall D. Exhaust hood E. Clamps B H F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside. Determine vent path: ■■Select route that will provide straightest and most direct path outdoors. ■■Plan installation to use fewest number of elbows and turns. ■■When using elbows or making turns, allow as much room as possible. ■■Bend vent gradually to avoid kinking. ■■Use as few 90° turns as possible. Determine vent length and elbows needed for best drying performance: ■■Use the following Vent System Chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in Vent system chart. Exhaust systems longer than those specified will: ■■Shorten life of dryer. ■■Reduce performance, resulting in longer drying times and increased energy usage. The Vent System Chart provides venting requirements that will help achieve best drying performance. Number of 90° elbows Vent System Chart Type of vent Box/louvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m) 2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m) 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

14
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installation:
Vent System Chart
Number of
90° elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The Vent System Chart provides venting requirements that will
help achieve best drying performance.
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
Use the following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE:
Do not use vent runs longer than those specified
in Vent system chart.
Exhaust systems longer than those specified will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
A.
Dryer
B
Elbow
C.
Wall
D.
Exhaust hood
E.
Clamps
F.
Rigid metal or
flexible metal vent
G. Vent length
necessary to
connect elbows
H.
Exhaust outlet
A
B
C
D
E
F
B
G
H