Xerox 5400DX Technical Reference - Page 2
PHASER 5400 Technical Instructions
UPC - 042215476539
View all Xerox 5400DX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
2 Photo 8 Step 3 Rotate the cartridge to the fill plug side. Repeat Step 2 to remove the cartridge pin. Separate the cartridge sections and put aside the toner unit. (See Photo 5&6) Photo 9 Photo 5 Photo 10 Photo 6 Photo 11 Step 4 Remove the screws holding the metal drum axial and remove drum axial. Remove screws holding white plastic drum with contact and remove white drum axial. (See Photo 7&8) Photo 12 Photo 7 Photo 13 PHASER 5400 Technical Instructions Step 5 Remove the drum and set aside in a light protected area. Step 6 Remove PCR roller from saddle blocks. Set PCR roller aside. (See Photo 9) Step 7 Remove the screws to the wiper blade and lift out wiper blade. Remove waste toner using a vacuum or dry, compressed air. (See Photo 10) Step 8 Clean wiper blade with a soft dry cloth or dry, compressed air. Apply padding powder to the blade edge and reinstall. (See Photo 11&12) Step 9 Clean PCR saddle blocks with cotton swab and Anhydrous Isopropyl Alcohol. Clean PCR using a dry, soft, lint-free cloth. NOTE: If needed, de-ionized water can be used to clean the PCR. (See Photo 13&14) Photo 14