Yamaha 24N DME64N/24N V1.2 Supplemental notes - Page 6

Message List

Page 6 highlights

Message List Message Cannot Select CAS. In Sync Err CAS. Out Sync Err Connecting Download Success Downloading DSP Power Shortage Duplicate IP Adr. File Operating Flash Rom Full Illegal MAC Adr. Invalid IP Adr. Invalid Password Low Battery MIDI Port In Use Network Busy Network Error Network Setup No Battery No Current Scene No MAC Adr. Panel Locked Panel Unlocked Param Access Err Param Set Err Content Corrective Action There is no selectable item in the scene or monitoring point list. Data is not registered.Register the data to be used in DME Designer. The word clock input from the [CASCADE IN] terminal is Recheck the settings for using the word clock that not synchronized with the DME64N word clock. synchronizes the DME64N and external devices. The word clock input from the [CASCADE OUT] terminal is Recheck the settings for using the word clock that not synchronized with the DME64N word clock. synchronizes the DME64N and external devices. Searching for DMEs in the network and connecting them. - The DME64N/24N program update or restoration was - successful. Updating the DME64N/24N program. Do NOT turn off the - power while this display is on the screen. The audio signal is muted without being input or output, To operate with all word clocks, set the word clock in DME because the DSP resources are insufficient. This message Designer to 96 kHz when creating a configuration. may be displayed when a configuration created at 44.1 or 48 kHz is operated at 88.2 or 96 kHz. An IP address is duplicated. Change the settings so that there are no duplicate IP address. Scene-related data (configuration, component, etc.) from - the computer is in operation. Do NOT turn off the power while this display is on the screen. The flash memory used for saving data has become full. Erase unused data such as configurations, presets, and audio data. This is an invalid MAC address. Since this is likely to be a device failure, contact a Yamaha electric sound service outlet listed at the end of this manual (page 79). An IP address is invalid. Set a valid IP address. The password is incorrect. Enter the correct password. If you have forgotten the password, contact a Yamaha electric sound service outlet listed at the end of this manual (page 79). Battery capacity is running low. Stop using the unit immediately and contact a Yamaha electric sound service outlet listed at the end of this manual (page 79). The USB port being used for communication with DME Designer has been selected as a host. Set Host on the utility screen's MIDI page to another port. Traffic in the network is congested. Communication will take time. Check the devices connected to the network. If there are a large number of connected devices, reduce their number. If LinkMode is set to 10BASE-T, traffic speed may improve if the setting is changed to 100BASE-TX. An error like the following has occurred on the network: Investigate the cause of the error and eliminate it. • A cable has become disconnected. • The power to a connected hub or router is cut off. • A cable is in an unsuitable condition (such as something heavy resting on the cable). (Static electricity may be having an effect.) Various settings for connecting to the network are being - made. The battery is exhausted. When the power is turned OFF, the current settings will be lost and the unit will return to its initial settings. Stop using the unit immediately and contact a Yamaha electric sound service outlet listed at the end of this manual (page 79). There is no current scene. This is displayed when scene data has not been sent even once. Create data using DME Designer, and synchronize DME Designer and the DME64N/24N unit. No MAC address is set. Since this is likely to be a device failure, contact a Yamaha electric sound service outlet listed at the end of this manual (page 79). Panel lock is set, and the panel cannot be operated. Panel lock may have been set by the administrator to prevent unexpected data changes caused by erroneous user operations. To use the panel, hold the [CANCEL] button down for at least two seconds. This clears the panel lock. Panel lock has been cleared. Panel operations are - possible. Cannot display current settings. The component version may be old. Update to the latest component. Cannot change current settings. The component version may be old. Update to the latest component. 6 Notes for DME64N/DME24N Version 1.2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Notes for DME64N/DME24N Version 1.2
6
Message List
Message
Content
Corrective Action
Cannot Select
There is no selectable item in the scene or monitoring
point list.
Data is not registered.Register the data to be used in DME
Designer.
CAS. In Sync Err
The word clock input from the [CASCADE IN] terminal is
not synchronized with the DME64N word clock.
Recheck the settings for using the word clock that
synchronizes the DME64N and external devices.
CAS. Out Sync Err
The word clock input from the [CASCADE OUT] terminal is
not synchronized with the DME64N word clock.
Recheck the settings for using the word clock that
synchronizes the DME64N and external devices.
Connecting
Searching for DMEs in the network and connecting them.
Download Success
The DME64N/24N program update or restoration was
successful.
Downloading
Updating the DME64N/24N program. Do NOT turn off the
power while this display is on the screen.
DSP Power Shortage
The audio signal is muted without being input or output,
because the DSP resources are insufficient. This message
may be displayed when a configuration created at 44.1 or
48 kHz is operated at 88.2 or 96 kHz.
To operate with all word clocks, set the word clock in DME
Designer to 96 kHz when creating a configuration.
Duplicate IP Adr.
An IP address is duplicated.
Change the settings so that there are no duplicate IP
address.
File Operating
Scene-related data (configuration, component, etc.) from
the computer is in operation. Do NOT turn off the power
while this display is on the screen.
Flash Rom Full
The flash memory used for saving data has become full.
Erase unused data such as configurations, presets, and
audio data.
Illegal MAC Adr.
This is an invalid MAC address.
Since this is likely to be a device failure, contact a Yamaha
electric sound service outlet listed at the end of this
manual (page 79).
Invalid IP Adr.
An IP address is invalid.
Set a valid IP address.
Invalid Password
The password is incorrect.
Enter the correct password. If you have forgotten the
password, contact a Yamaha electric sound service outlet
listed at the end of this manual (page 79).
Low Battery
Battery capacity is running low.
Stop using the unit immediately and contact a Yamaha
electric sound service outlet listed at the end of this
manual (page 79).
MIDI Port In Use
The USB port being used for communication with DME
Designer has been selected as a host.
Set Host on the utility screen’s MIDI page to another port.
Network Busy
Traffic in the network is congested. Communication will
take time.
Check the devices connected to the network. If there are a
large number of connected devices, reduce their number.
If LinkMode is set to 10BASE-T, traffic speed may improve
if the setting is changed to 100BASE-TX.
Network Error
An error like the following has occurred on the network:
• A cable has become disconnected.
• The power to a connected hub or router is cut off.
• A cable is in an unsuitable condition (such as something
heavy resting on the cable).
(Static electricity may be having an effect.)
Investigate the cause of the error and eliminate it.
Network Setup
Various settings for connecting to the network are being
made.
No Battery
The battery is exhausted.
When the power is turned OFF, the current settings will be
lost and the unit will return to its initial settings. Stop using
the unit immediately and contact a Yamaha electric sound
service outlet listed at the end of this manual (page 79).
No Current Scene
There is no current scene.
This is displayed when scene data has not been sent even
once. Create data using DME Designer, and synchronize
DME Designer and the DME64N/24N unit.
No MAC Adr.
No MAC address is set.
Since this is likely to be a device failure, contact a Yamaha
electric sound service outlet listed at the end of this
manual (page 79).
Panel Locked
Panel lock is set, and the panel cannot be operated.
Panel lock may have been set by the administrator to
prevent unexpected data changes caused by erroneous
user operations.
To use the panel, hold the [CANCEL] button down for at
least two seconds. This clears the panel lock.
Panel Unlocked
Panel lock has been cleared. Panel operations are
possible.
Param Access Err
Cannot display current settings.
The component version may be old. Update to the latest
component.
Param Set Err
Cannot change current settings.
The component version may be old. Update to the latest
component.