Zenith SL-5597-BZ-E User Manual - Page 1

Zenith SL-5597-BZ-E - Heath - Quartz Halogen Motion-Sensing Twin Security Light Manual

Page 1 highlights

DualBrite® Motion Sensor Light Control Model 5597 Requirements • The light control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualified electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. Meets the ENERGY STAR® guidelines when DualBrite® function is off and ON-TIME is 1 or 5 minutes. Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • DualBrite® Timer. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). This package includes: Lamp Holders Rubber Plug OPERATION Mode: Test Auto Manual Accent On-Time 5 Seconds 1, 5, or 20 Min To Dawn* 3, 6 Hr, to Dawn Works: Day Night xx x x x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. TEST Put ON-TIME switch ON-TIME on the sensor bottom to TEST and the DualBrite® switch OFF. TEST 1 5 20 DualBrite® Off 3 6 Dusk to Dawn AUTO Plastic Hanger Put the ON-TIME switch in the 1, 5, or 20 minute position. ON-TIME TEST 1 5 20 Cover Plate Sensor Light Control 2 Wire Connectors Mounting Bolt Mounting Strap 2 Lamps (installed) 6 Screws (3 sizes included) Gasket MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second then back on to toggle between AUTO 1 Second OFF and MANUAL MODE. then... Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position. ... back on. © 2007 HeathCo LLC 595-5679-08

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

© 2007 HeathCo LLC
595-5679-08
D
UAL
B
RITE
®
Motion Sensor
Light Control
Model 5597
Light Control
2 Lamps
(installed)
Cover Plate
Sensor
Lamp Holders
This package includes:
TEST
TEST
1 5 20
ON-TIME
Off
3 6 Dusk to
Dawn
D
UAL
B
RITE
®
Put ON-TIME switch
on the sensor bottom
to TEST and the
D
UAL
-
B
RITE
®
switch OFF.
OPERATION
* resets to Auto Mode at dawn.
ON-TIME
TEST
1 5 20
... back on.
1 Second OFF
then...
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Note:
When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Mode:
On-Time
Works: Day Night
Test
5 Seconds
x
x
Auto
1, 5, or 20 Min
x
Manual
To Dawn*
x
Accent
3, 6 Hr, to Dawn
x
AUTO
MANUAL MODE
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
D
UAL
B
RITE
®
Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Wire
Connectors
Meets the ENERGY STAR
®
guidelines
when
D
UAL
B
RITE
®
function is off and
ON-TIME is 1 or 5 minutes.