Zenith SL-5797-NB-C User Guide - Page 5

Specifications, Troubleshooting Guide

Page 5 highlights

SPECIFICATIONS Range Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature] Sensing Angle Up to 270° Electrical Load Up to 200 Watt Maximum Incan- descent [Up to 100 Maximum each lamp holder]. Power Requirements. . 120 VAC, 60 Hz Operating Modes. . . . . TEST, AUTO and MANUAL MODE Lamp Modes Normal, Soft, Flash Time Delay 1, 5, 20 minutes Replacement lamp. . . . T4, 100W maximum G8 halogen bi-pin 120 VAC DualBrite® Timer. . . . . Off, 3, 6 hours, Dusk-to-Dawn HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold. TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE Lights will not come on. 1. Light switch is turned off. 2. Light is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turn-off is in effect (recheck after dark). 5. Incorrect circuit wiring, if this is a new installation. 6. Re-aim the sensor to cover desired area. Lights come on in daylight. 1. Light control may be installed in a relatively dark location. 2. Light control is in Test. (Set control switch to an ON-TIME position). Lights come on for no apparent reason. 1. Light control may be sensing small animals or automobile traffic (re-aim sensor). 2. Range is set too high. (Reduce Range). 3. DualBrite® Timer is on. Lights turn off too late in Dusk-to-Dawn setting 1. Sensor is in a relatively dark location. (Relocate sensor, or use 3 hr or 6 hr setting.) Lights stay on continuously. 1. A lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor. (Reposition the lamp away from the sensor or nearby objects). 2. Light control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface. (Reposition sensor. Reduce Range). 3. Light control is in Manual Mode. (Switch to Auto.) Lights flash on and off. 1. Heat or light from the lamps may be turning the light control on and off. (Reposition the lamps away from the sensor). 2. Heat being reflected from other objects may be affecting the sensor. (Reposition sensor). 3. Light control is in the Test mode and warming up. (Flashing is normal under these conditions. Turn Boost off.) 4. Light control is in Flash mode. (An initial start-up flashing is normal in this mode. Select Normal or Soft mode to turn flash mode off). Lights flash once, then stay 1. Sensor is detecting its own lights. (Reposition lamps to keep area below the sensor off in Manual Mode. relatively dark.) 598-1315-02 

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

5
598-1315-02
SPECIFICATIONS
Range
............
Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Sensing Angle
......
Up to 270°
Electrical Load
......
Up to 200 Watt Maximum Incan-
descent [Up to 100 Maximum
each lamp holder].
Power Requirements .
120 VAC, 60 Hz
Operating Modes
....
TEST, AUTO and MANUAL
MODE
Lamp Modes
.......
Normal, Soft, Flash
Time Delay
........
1, 5, 20 minutes
Replacement lamp.
.
.
T4, 100W maximum G8 halogen
bi-pin 120 VAC
D
UAL
B
RITE
®
Timer
....
Off, 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSE
Lights will not come on.
1.
Light switch is turned off.
2.
Light is loose or burned out.
3.
Fuse is blown or circuit breaker is turned off.
4.
Daylight turn-off is in effect
(recheck after dark)
.
5.
Incorrect circuit wiring, if this is a new installation.
6.
Re-aim the sensor to cover desired area.
Lights come on in daylight.
1.
Light control may be installed in a relatively dark location.
2.
Light control is in Test.
(Set control switch to an ON-TIME position)
.
Lights come on for no ap-
parent reason.
1.
Light control may be sensing small animals or automobile traffic
(re-aim sensor)
.
2.
Range is set too high.
(Reduce Range)
.
3.
D
UAL
B
RITE
®
Timer is on.
Lights turn off too late in
Dusk-to-Dawn setting
1.
Sensor is in a relatively dark location.
(Relocate sensor, or use 3 hr or 6 hr setting.)
Lights stay on
continuously.
1.
A lamp is positioned too close to the sensor or pointed at nearby objects that cause heat
to trigger the sensor.
(Reposition the lamp away from the sensor or nearby objects)
.
2.
Light control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted
heat-reflective surface.
(Reposition sensor. Reduce Range)
.
3.
Light control is in Manual Mode.
(Switch to Auto.)
Lights flash on and off.
1.
Heat or light from the lamps may be turning the light control on and off.
(Reposition
the lamps away from the sensor)
.
2.
Heat being reflected from other objects may be affecting the sensor.
(Reposition sen-
sor)
.
3.
Light control is in the Test mode and warming up.
(Flashing is normal under these
conditions. Turn Boost off.)
4.
Light control is in Flash mode.
(An initial start-up flashing is normal in this mode. Select
Normal or Soft mode to turn flash mode off)
.
Lights flash once, then stay
off in Manual Mode.
1.
Sensor is detecting its own lights.
(Reposition lamps to keep area below the sensor
relatively dark.)