ZyXEL Elite 2864I User Guide - Page 194
<cml>, <scs>, <vsr>
View all ZyXEL Elite 2864I manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 194 highlights
• AT+VSM= This command causes the DCE to select a compression method as follows: 2 3 30 4 Compression Method Description ZyXEL 2-bit ADPCM (default) ZyXEL 3-bit ADPCM ZyXEL new 3-bit ADPCM ZyXEL 4-bit ADPCM The DCE returns the OK result code if the DCE accepts this command, or it returns the ERROR result code if the value is out of range. • AT+VSM? This command causes the DCE to report the current compression setting in the following form: ;; OK where is the compression method label. is the silence compression sensitivity. is the voice sampling rate. • AT+VSM=? This command causes the DCE to report the compression methods supported. The response is as follows: 2;ADPCM;2;0;(9600) 3;ADPCM;3;0;(9600) 30;ADPCM;3;0;(9600) 4;ADPCM;4;0;(9600) OK The first item in each line is the compression method label, the second item is the compression scheme, the third item is the number of bits per sample, the fourth item is the silence detection threshold level, and the fifth item is the sampling rate. • AT+VTD=, This command causes the DCE to set the default DTMF tone generation duration and comma pause intercal used in conjunction with AT+VTS command. The range of and is from 0 to 255. The units are 10 msec. The default value for is 50 (500 ms) and for is 7 (70 ms). The DCE returns the OK result code if the DCE accepts this command, or it returns the ERROR result code if any of the or values is out of range. 16-18