ZyXEL Elite 2864I User Guide - Page 90
Register, Default, Description
View all ZyXEL Elite 2864I manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Register Default Min. Max. Description S7 60 0 255 Sets the number of seconds the modem will wait for a carrier. If the modem does not detect a carrier within this time limit, it hangs up and returns the NO CARRIER result code. S8 2 0 255 Sets the duration of delay generated by the comma (,) dial modifier. Also sets the pause between command re-execution for the repeat (>) command. S9 6 0 255 Sets the duration, in tenths of a second, that the remote modem's carrier signal must be present before recognition. When in non-FSK or half-duplex operation, the modem ignores the setting of this register. S10 7 0 255 Sets the duration, in tenths of a second, that the modem will wait after loss of carrier before hanging up. This guard time allows the modem to distinguish between a line hit, or any other cause that momentarily breaks the connection, and a true disconnection (hanging up) by the remote modem. S11 70 0 255 Sets the duration and spacing, in milliseconds, in touch-tone dialing. Note: The numerical values of the ASCII codes are always given as decimals. If you enter values from the LCD front panel, you must convert these values to hexadecimal (hex) values. 8-4