Battery MAINTENANCE Battery Charging (Sealed Battery) NOTE: Always verify battery condition before and 1-2 hours after the end of charging. State of Charge 100% 75%-100% Voltage 12.8-13.0 volts 12.5-12.8 volts Action None, check at 3 mos. from date of manufacture May need slight charge, if no charge given, check in 3 months Needs charge Needs charge Needs charge with desulfating charger Charge Time (Using constant current charger @ standard amps specified on top of battery) None required 3-6 hours 50%-75% 25%-50% 0%-25% 12.0-12.5 volts 11.5-12.0 volts 11.5 volts or less 5-11 hours At least 13 hours, verify state of charge At least 20 hours Fuses The vehicle wire harness is protected by self-resetting circuit breakers (fuses). Do not attempt to replace these fuses. If the engine stops or will not start, or if you experience other electrical failures, locate and correct any short circuits that may have caused a tripped fuse. The fuse should automatically reset. NOTE: If you suspect that a fuse is not working properly, please see your Polaris dealer for diagnosis and repair. 101