3Com 4500G Getting Started Guide - Page 84

Switch 4500G 48-Port, Physical Dimensions, Environmental, Requirements, Safety, Heat Dissipation - in lbs

Page 84 highlights

84 APPENDIX B: TECHNICAL SPECIFICATIONS Switch 4500G 48-Port Physical Dimensions Environmental Requirements Operating Temperature Storage Temperature Operating Humidity Standards Safety Agency Certifications EMC Emissions Immunity Heat Dissipation Power Supply (AC) Line Frequency Input Voltage Current Rating Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 274 mm (10.8 in.) Weight: 4.7kg (10.9 lbs) 0 ° to 40 °C (32 ° to 104 °F) −10 ° to +70 °C (14 ° to 158 °F) 95% non-condensing EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13). UL 60950-1, EN 60950-1, CSA 22.2 No. 60950-1, IEC 60950-1. CISPR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A, ICES-003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3 EN 55024 80 watts maximum (275 BTU/hour maximum) 50/60Hz 100-240 VAC 2.0A (amps) maximum

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

84
A
PPENDIX
B: T
ECHNICAL
S
PECIFICATIONS
Switch 4500G 48-Port
Physical Dimensions
Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x
Depth: 274 mm (10.8 in.)
Weight: 4.7kg (10.9 lbs)
Environmental
Requirements
Operating Temperature
0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature
10 ° to +70 °C (14 ° to 158 °F)
Operating Humidity
95% non-condensing
Standards
EN60068 to 3Com schedule (Package testing: paras
2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1,
2.2, 2.30 and 2.13).
Safety
Agency Certifications
UL 60950-1, EN 60950-1, CSA 22.2 No. 60950-1,
IEC 60950-1.
EMC
Emissions
CISPR 22 Class A, EN55022 Class A, FCC Part 15
Subpart B Class A,
ICES-003 Class A, VCCI Class A,
EN61000-3-2, EN61000-3-3
Immunity
EN 55024
Heat Dissipation
80 watts maximum (275 BTU/hour maximum)
Power Supply (AC)
Line Frequency
50/60Hz
Input Voltage
100–240 VAC
Current Rating
2.0A (amps) maximum